NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM385157 Query DataSets for GSM385157
Status Public on Mar 08, 2010
Title Human hepatitis C virus liver biopsy sample 1 Replicate 2
Sample type RNA
 
Channel 1
Source name human hepatitis C virus liver biopsy sample
Organism Homo sapiens
Characteristics sample: HCV negative
Extracted molecule total RNA
Extraction protocol Frozen liver tissues were disrupted in Trizol Reagent (Invitrogen, Carlsbad, CA) using a Polytron homogenizer (PowerGene 700, Fisher Scientific), and total RNA was isolated according to the Trizol protocol. The quality of amplified RNA was evaluated by capillary electrophoresis using an Agilent 2100 Bioanalyzer (Agilent Technologies, Palo Alto, CA)
Label Cy5
Label protocol Probe labeling was performed using Low RNA Input Fluorescent Linear Amplification kit (Agilent Technologies, Santa Clara, CA). Total input RNA was 200-400ng per reaction.
 
Channel 2
Source name common reference sample
Organism Homo sapiens
Characteristics sample: Reference
Extracted molecule total RNA
Extraction protocol Frozen liver tissues were disrupted in Trizol Reagent (Invitrogen, Carlsbad, CA) using a Polytron homogenizer (PowerGene 700, Fisher Scientific), and total RNA was isolated according to the Trizol protocol. The quality of amplified RNA was evaluated by capillary electrophoresis using an Agilent 2100 Bioanalyzer (Agilent Technologies, Palo Alto, CA)
Label Cy3
Label protocol Probe labeling was performed using Low RNA Input Fluorescent Linear Amplification kit (Agilent Technologies, Santa Clara, CA). Total input RNA was 200-400ng per reaction.
 
 
Hybridization protocol A single experiment comparing two mRNA samples was done with four replicate Human 1A (V2)22K oligonucleotide expression arrays (Agilent Technologies) using the dye label reverse technique (Agilent Microarray protocol, version 2). The common reference sample was pooled RNA obtained from normal donor livers.
Scan protocol Scanned on an Agilent G2505B Scanner
Description Hepatitis C virus positive (HCV+) and negative (HCV-) tissue samples from percutaneous core needle biopsy specimens from liver transplantation patients were obtained according to clinical protocols at the University of Washington Medical Center.
Data processing Agilent Feature Extraction v9.5.3, default mRNA parameters. For a complete description of the columns in the supplemental array data files, see Agilent's Reference Guide for Feature Extraction Software v9.5, http://www.chem.agilent.com/en-US/Search/Library/_layouts/Agilent/PublicationSummary.aspx?whid=50416&liid=1568
 
Submission date Mar 20, 2009
Last update date Mar 08, 2010
Contact name Xinxia Peng
E-mail(s) xinxiap@u.washington.edu
Organization name University of Washington
Department Microbiology
Lab Katze
Street address Rosen Building, 960 Republican St.
City Seattle
State/province WA
ZIP/Postal code 98109
Country USA
 
Platform ID GPL887
Series (2)
GSE15331 mRNA expression in human hepatitis c virus (HCV) liver biopsy samples
GSE15387 microRNA and mRNA expression in human hepatitis C Virus

Data table header descriptions
ID_REF
VALUE log(REDsignal/GREENsignal) per feature (processed signals used, base 10)

Data table
ID_REF VALUE
1 -2.982709174
2 0
3 -0.01154053181
4 0.02292399225
5 0.07402419706
6 -0.06050102649
7 -3.412627939
8 -0.04907953102
9 -0.01746059058
10 -0.2451175386
11 -0.2939000604
12 -0.3641812398
13 0.1924536021
14 -3.109231055
15 0.07041010686
16 -0.1385207605
17 -0.2496237113
18 -0.02058538866
20 -0.1195939663
21 -3.101717428

Total number of rows: 22575

Table truncated, full table size 420 Kbytes.




Supplementary file Size Download File type/resource
GSM385157_US23502338_251209753399_S01_A01_22k_.15.txt.gz 5.8 Mb (ftp)(http) TXT
Processed data included within Sample table

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap