NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM385108 Query DataSets for GSM385108
Status Public on Mar 08, 2010
Title Human hepatitis C virus liver biopsy sample 20 Replicate 1
Sample type RNA
 
Channel 1
Source name human hepatitis C virus liver biopsy sample
Organism Homo sapiens
Characteristics sample: HCV positive
Extracted molecule total RNA
Extraction protocol Frozen liver tissues were disrupted in Trizol Reagent (Invitrogen, Carlsbad, CA) using a Polytron homogenizer (PowerGene 700, Fisher Scientific), and total RNA was isolated according to the Trizol protocol. The quality of amplified RNA was evaluated by capillary electrophoresis using an Agilent 2100 Bioanalyzer (Agilent Technologies, Palo Alto, CA)
Label Cy5
Label protocol Probe labeling was performed using Low RNA Input Fluorescent Linear Amplification kit (Agilent Technologies, Santa Clara, CA). Total input RNA was 200-400ng per reaction.
 
Channel 2
Source name common reference sample
Organism Homo sapiens
Characteristics sample: Reference
Extracted molecule total RNA
Extraction protocol Frozen liver tissues were disrupted in Trizol Reagent (Invitrogen, Carlsbad, CA) using a Polytron homogenizer (PowerGene 700, Fisher Scientific), and total RNA was isolated according to the Trizol protocol. The quality of amplified RNA was evaluated by capillary electrophoresis using an Agilent 2100 Bioanalyzer (Agilent Technologies, Palo Alto, CA)
Label Cy3
Label protocol Probe labeling was performed using Low RNA Input Fluorescent Linear Amplification kit (Agilent Technologies, Santa Clara, CA). Total input RNA was 200-400ng per reaction.
 
 
Hybridization protocol A single experiment comparing two mRNA samples was done with four replicate Human 1A (V2)22K oligonucleotide expression arrays (Agilent Technologies) using the dye label reverse technique (Agilent Microarray protocol, version 2). The common reference sample was pooled RNA obtained from normal donor livers.
Scan protocol Scanned on an Agilent G2505B Scanner
Description Hepatitis C virus positive (HCV+) and negative (HCV-) tissue samples from percutaneous core needle biopsy specimens from liver transplantation patients were obtained according to clinical protocols at the University of Washington Medical Center.
Data processing Agilent Feature Extraction v9.5.3, default mRNA parameters. For a complete description of the columns in the supplemental array data files, see Agilent's Reference Guide for Feature Extraction Software v9.5, http://www.chem.agilent.com/en-US/Search/Library/_layouts/Agilent/PublicationSummary.aspx?whid=50416&liid=1568
 
Submission date Mar 20, 2009
Last update date Mar 08, 2010
Contact name Xinxia Peng
E-mail(s) xinxiap@u.washington.edu
Organization name University of Washington
Department Microbiology
Lab Katze
Street address Rosen Building, 960 Republican St.
City Seattle
State/province WA
ZIP/Postal code 98109
Country USA
 
Platform ID GPL887
Series (2)
GSE15331 mRNA expression in human hepatitis c virus (HCV) liver biopsy samples
GSE15387 microRNA and mRNA expression in human hepatitis C Virus

Data table header descriptions
ID_REF
VALUE log(REDsignal/GREENsignal) per feature (processed signals used, base 10)

Data table
ID_REF VALUE
1 -2.809901592
2 -0.8931573315
3 -0.2623803511
4 -0.3231392328
5 -0.241813825
6 -0.08747465916
7 -3.108621918
8 -0.1449536428
9 -0.06313996927
10 0.08890548632
11 -0.04288680097
12 0.5013438521
13 0.1174545601
14 -3.163806312
15 -0.2277247717
16 0.6924619591
17 0
18 0.2259392591
20 0
21 -2.972784249

Total number of rows: 22575

Table truncated, full table size 415 Kbytes.




Supplementary file Size Download File type/resource
GSM385108_US23502338_251209752624_S01_A01_22k_.15.txt.gz 5.8 Mb (ftp)(http) TXT
Processed data included within Sample table

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap