gender: female age: 62 years tissue origin: breast tissue: ductal carcinoma in situ
Treatment protocol
Mastectomised breast and the axillary lymph nodes kept in formalin
Extracted molecule
total RNA
Extraction protocol
Twenty μm thick FFPE sections were cut and mounted on PALM Membrane Slides. Under direct microscopic visualization, tissues of interest were micro-dissected using PALM non-contact Laser catapulsion instrument (P.A.L.M. Microlaser Technologies, Carl Zeiss Ltd). Total RNA, including miRNAs, was extracted with the TRIzol reagent (Invitrogen, supplied by Fisher Scientific UK Ltd) according to the manufacturer’s instructions. Total RNA was quantified with Quant-iT RiboGreen RNA Quantitation Kit (Fisher Scientific UK Ltd), which is an accurate method of measuring total RNA with a detection limit of 0.001-1ng/µl. RNA purity and RNA integrity number (RIN) were determined on an Agilent 2100 Bioanalyzer and RNA 6000 NanoLabChip Kits (both Agilent Technologies, Santa Clara, USA).
Label
Cy3
Label protocol
MiRNAs extracted from laser microdissected tissue components were profiled using Agilent microRNA microarray profiling system (Agilent Technologies, Santa Clara, USA). Total RNA samples were spiked using the MicroRNA Spike-In Kit (Agilent Technologies, Santa Clara, USA) to evaluate efficiencies of labelling and hybridisation. Total RNA was treated with Calf Intestinal Alkaline Phosphatase (CIP), and then 100 ng of total RNA was used per sample to initiate a labelling reaction. Ligation master mix for T4 RNA ligase, which includes Cyanine 3-Cytidine biphosphate (Cyanine 3-pCp) (Complete miRNA Labelling and Hyb Kit, Agilent Technologies, Santa Clara, USA) was used to label the dephosphorylated RNA.
Hybridization protocol
Cyanine-3-labelled miRNA samples were hybridised to human miRNA microarrays (Release 16.0, 8x60K) (Agilent Technologies, Santa Clara, USA) at 55°C for 20 hrs. Microarray slides were washed with increasing stringency (Gene Expression Wash Buffers, Agilent Technologies, Santa Clara), and subsequently dried with acetonitrile (Sigma-Aldrich, St. Louis, USA).
Scan protocol
Fluorescent signal intensities were detected on an Agilent Microarray Scanner (Agilent Technologies, Santa Clara, USA) using the Scan Control A.8.4.1 Software (Agilent Technologies, Santa Clara, USA).
Description
miRNAs expression profiling using Human miRNA Microarrays Release 16.0 (Agilent Technologies) [2730-2]
Data processing
Fluorescent signal intensities were extracted from the images with the Feature Extraction 10.7.3.1 Software (Agilent Technologies, Santa Clara, USA). The raw signal values were 'normalized to the 90th percentile' when importing the FE files into GeneSpring (the analysis software). Only the top 20% of probes on the array typically had any detectable signal so shifting to the 90th percentile meant the median line was around the centre of this expressed set.