NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM123063 Query DataSets for GSM123063
Status Public on Sep 08, 2006
Title MAQC_ABI_3_D4
Sample type RNA
 
Source name MAQC sample D, i.e., MAQC samples A and B mixed at 25%:75% ratio (A:B).
Organism Homo sapiens
Characteristics NA

Extracted molecule total RNA
Label Chemiluminescence - Digoxigenin
Label protocol Digoxigenin-UTP labeled cRNA was generated from 1 µg of total RNA for each MAQC sample (A, B, C, D) using Applied Biosystems NanoAmp RT-IVT Labeling Kit (P/N 4365715) according to the manufacturer’s protocol.
 
Hybridization protocol Array hybridization, array processing, chemiluminescence detection, image acquisition, and analysis were performed using Applied Biosystems Chemiluminescence Detection Kit and Applied Biosystems 1700 Chemiluminescent Microarray Analyzer following manufacturer’s protocol.
Scan protocol Chemiluminescent Detection Kit (P/N 4339627, http://docs.appliedbiosystems.com/pebiodocs/04339627.pdf) and Chemiluminescent Microarray Analyzer User Guide (P/N 4338852B).
Description NA
Data processing The Expression Array System Software suite performs the auto-gridding, feature extraction, fluorescence normalization, and signal data generation. The quantification data contain many distinct measurements for each probe, including the three basic measurements: Signal, S/N, and Flag values. The Signal value is the fully corrected, background subtracted measurement of chemiluminescent signal for gene expression values. The S/N value represents the ratio of signal above noise, or the measurement uncertainty of the probe signal, and can be used as a confidence level for the probe measurement. An S/N of 3 represents approximately a 99.95% confidence that the probe is detected above the background noise. In situations where the probe showed S/N < 1, the signal measurement is replaced with a 1 SDEV upper limit based on its probe signal SDEV.
 
Submission date Jul 24, 2006
Last update date Aug 17, 2006
Contact name Leming Shi
E-mail(s) lemingshi@fudan.edu.cn
Phone +86-18616827008
Organization name Fudan University
Department School of Life Sciences
Lab Center for Pharmacogenomics
Street address 2005 Songhu Road
City Shanghai
ZIP/Postal code 200438
Country China
 
Platform ID GPL2986
Series (1)
GSE5350 MicroArray Quality Control (MAQC) Project

Data table header descriptions
ID_REF Manufacturer's probe ID
VALUE The signal value is the fully corrected, background subtracted measurement of chemiluminescent signal for gene expression values. Data were quantile-normalized per test site (20 arrays).
Flag_Detection An S/N of 3 represents approximately a 99.95% confidence that the probe is detected above the background noise.

Data table
ID_REF VALUE Flag_Detection
100002 98589.383 57.17
100003 109.819 -0.51
100027 99.864 2.5
100036 14219.104 35.87
100037 18741.65 56.73
100039 6104.14 50.71
100044 3568.145 20.91
100045 257.323 -0.27
100051 128.475 -1.71
100052 3946.275 32.45
100057 2174.973 11.45
100058 35170.398 69.42
100060 1180.306 5.97
100062 294.041 0.93
100064 982.742 28.55
100079 103136.25 57.89
100089 9941.522 31.01
100093 5645.874 68.26
100095 157.059 1.4
100100 18495.82 45.82

Total number of rows: 32878

Table truncated, full table size 682 Kbytes.




Supplementary file Size Download File type/resource
GSM123063_ABI_3_D4.txt.gz 309.5 Kb (ftp)(http) TXT

| NLM | NIH | GEO Help | Disclaimer | Accessibility |