NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM123016 Query DataSets for GSM123016
Status Public on Sep 08, 2006
Title MAQC_ABI_1_C2
Sample type RNA
 
Source name MAQC sample C, i.e., MAQC samples A and B mixed at 75%:25% ratio (A:B).
Organism Homo sapiens
Characteristics NA

Extracted molecule total RNA
Label Chemiluminescence - Digoxigenin
Label protocol Digoxigenin-UTP labeled cRNA was generated from 1 µg of total RNA for each MAQC sample (A, B, C, D) using Applied Biosystems NanoAmp RT-IVT Labeling Kit (P/N 4365715) according to the manufacturer’s protocol.
 
Hybridization protocol Array hybridization, array processing, chemiluminescence detection, image acquisition, and analysis were performed using Applied Biosystems Chemiluminescence Detection Kit and Applied Biosystems 1700 Chemiluminescent Microarray Analyzer following manufacturer’s protocol.
Scan protocol Chemiluminescent Detection Kit (P/N 4339627, http://docs.appliedbiosystems.com/pebiodocs/04339627.pdf) and Chemiluminescent Microarray Analyzer User Guide (P/N 4338852B).
Description NA
Data processing The Expression Array System Software suite performs the auto-gridding, feature extraction, fluorescence normalization, and signal data generation. The quantification data contain many distinct measurements for each probe, including the three basic measurements: Signal, S/N, and Flag values. The Signal value is the fully corrected, background subtracted measurement of chemiluminescent signal for gene expression values. The S/N value represents the ratio of signal above noise, or the measurement uncertainty of the probe signal, and can be used as a confidence level for the probe measurement. An S/N of 3 represents approximately a 99.95% confidence that the probe is detected above the background noise. In situations where the probe showed S/N < 1, the signal measurement is replaced with a 1 SDEV upper limit based on its probe signal SDEV.
 
Submission date Jul 24, 2006
Last update date Aug 17, 2006
Contact name Leming Shi
E-mail(s) lemingshi@fudan.edu.cn
Phone +86-18616827008
Organization name Fudan University
Department School of Life Sciences
Lab Center for Pharmacogenomics
Street address 2005 Songhu Road
City Shanghai
ZIP/Postal code 200438
Country China
 
Platform ID GPL2986
Series (1)
GSE5350 MicroArray Quality Control (MAQC) Project

Data table header descriptions
ID_REF Manufacturer's probe ID
VALUE The signal value is the fully corrected, background subtracted measurement of chemiluminescent signal for gene expression values. Data were quantile-normalized per test site (20 arrays).
Flag_Detection An S/N of 3 represents approximately a 99.95% confidence that the probe is detected above the background noise.

Data table
ID_REF VALUE Flag_Detection
100002 130151.531 73.21
100003 265.195 1.91
100027 182.253 -0.4
100036 12712.548 36.27
100037 23224.146 45.19
100039 3678.613 16.64
100044 617.436 5.79
100045 300.184 -0.44
100051 175.655 -1.96
100052 1290.816 10.9
100057 2592.226 5.59
100058 63731.055 60.96
100060 695.231 3.12
100062 1115.358 0.38
100064 2803.74 41.12
100079 147993.141 46.11
100089 9820.557 20.87
100093 13866.094 74.07
100095 430.412 -0.56
100100 36897.602 44.9

Total number of rows: 32878

Table truncated, full table size 681 Kbytes.




Supplementary file Size Download File type/resource
GSM123016_ABI_1_C2.txt.gz 286.0 Kb (ftp)(http) TXT

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap