U.S. flag

An official website of the United States government

Format

Send to:

Choose Destination

SRX10435265: GSM5208268: T20031; Plasmodium falciparum; RNA-Seq
1 ILLUMINA (Illumina HiSeq 4000) run: 29.3M spots, 8.8G bases, 3.2Gb downloads

Submitted by: NCBI (GEO)
Study: cDNA sequencing of Plasmodium falciparum field parasites 2015-2018
show Abstracthide Abstract
The objective of this study is to characterize gene expression signatures associated with in vivo artemisinin resistance phenotype and its transcriptional response to Artemisinin Combination Therapy (ACT) treatment . RNA-seq was applied to establish the global gene expression profiles for 196 and 180 isolates sampled from patients prior to and post to ACT treatment. Overall design: P. falciparum isolates were sampled from the whole blood of patients from 6 countries and 13 sites across Southeast Asia (Ramu in Bangladesh; Thabeikkyin, Pyay, Pyin Oo Lwin and Ann in Myanmar; Phusing and Khun Han in Thailand; Pailin, Pursat, Ratanakiri and Preah Vihear in Cambodia; Sekong in Laos; Bin Phuoc in Vietnam) from 2015 to 2018.
Sample: T20031
SAMN18474428 • SRS8570428 • All experiments • All runs
Library:
Instrument: Illumina HiSeq 4000
Strategy: RNA-Seq
Source: TRANSCRIPTOMIC
Selection: cDNA
Layout: PAIRED
Construction protocol: Total RNA was extracted using Trizol and ZYMO DirectZol96 extraction kit following protocol described in Kucharski, M., Tripathi, J., Nayak, S. et al. A comprehensive RNA handling and transcriptomics guide for high-throughput processing of Plasmodium blood-stage samples. Malar J 19, 363 (2020). Reverse transcription and cDNA synthesis was done following modifed Smart-Seq2 protocol using only oligo(d)T primers to enrich for mRNA transcripts (Kucharski, M., Tripathi, J., Nayak, S. et al. A comprehensive RNA handling and transcriptomics guide for high-throughput processing of Plasmodium blood-stage samples. Malar J 19, 363 (2020)). Purified amplicon (cDNA) was used to generate sequencing libraries using Illumina Nextera XT kit as described in manufacturer's protocol. Libraries were analyzed on the Bioanalyser High-Sensitivity DNA chips (Agilent, Cat. No.: 5067-4626), subsequently pooled (24 samples per lane) and sequenced on Illumina HiSeq4000 platform generating 150 bp paired end reads with 110 Gb data output generated per lane.
Experiment attributes:
GEO Accession: GSM5208268
Links:
Runs: 1 run, 29.3M spots, 8.8G bases, 3.2Gb
Run# of Spots# of BasesSizePublished
SRR1406050529,324,4518.8G3.2Gb2022-02-15

ID:
13831332

Supplemental Content

Search details

See more...

Recent activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...