U.S. flag

An official website of the United States government

Format

Send to:

Choose Destination

ERX288569: HPA RNA-seq normal tissues
1 ILLUMINA (Illumina HiSeq 2000) run: 31.7M spots, 6.4G bases, 2.7Gb downloads

Design: HPA RNA-seq normal tissues
Submitted by: SCIENCE FOR LIFE LABORATORY, STOCKHOLM, SWEDEN
Study: HPA RNA-seq normal tissues
show Abstracthide Abstract
RNA-seq was performed of tissue samples from 95 human individuals representing 27 different tissues in order to determine tissue-specificity of all protein-coding genes.
Sample: placenta_3a
SAMEA2162568 • ERS326999 • All experiments • All runs
Organism: Homo sapiens
Library:
Name: V76
Instrument: Illumina HiSeq 2000
Strategy: RNA-Seq
Source: TRANSCRIPTOMIC
Selection: cDNA
Layout: PAIRED
Construction protocol: The use of human tissue samples was approved by the Uppsala Ethical Review Board (Reference #2011/473). Tissues samples, collected within the infrastructure of an established biobank, were embedded in Optimal Cutting Temperature (O.C.T.) compound and stored at -80C. A hematoxylin-eosin (HE) stained frozen section (4um) was prepared from each sample using a cryostat and the CryoJane Tape-Transfer System (Instrumedics, St. Louis, MO, USA). Each slide was examined by a pathologist to ensure proper tissue morphology. Three sections (10um) were cut from each frozen tissue block and collected into a tube for subsequent RNA extraction. The tissue was homogenized mechanically using a 3 mm steel grinding ball (VWR). Total RNA was extracted from cell lines and tissue samples using the RNeasy Mini Kit (Qiagen, Hilden, Germany) according to the manufacturers instructions. The extracted RNA samples were analyzed using either an Experion automated electrophoresis system (Bio-Rad Laboratories, Hercules, CA, USA) with the standard-sensitivity RNA chip or an Agilent 2100 Bioanalyzer system(Agilent Biotechnologies, Palo Alto, USA) with the RNA 6000 Nano Labchip Kit. Only samples of high-quality RNA (RNA Integrity Number 7.5) were used in the following mRNA sample preparation for sequencing. Illumina Truseq RNA v2
Spot descriptor:
forward102  reverse

Experiment attributes:
Experimental Factor: organism part: placenta
Experimental Factor: individual: V76
Runs: 1 run, 31.7M spots, 6.4G bases, 2.7Gb
Run# of Spots# of BasesSizePublished
ERR31537531,687,6586.4G2.7Gb2013-12-12

ID:
558441

Supplemental Content

Recent activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...