Fitting success for three multifocal designs: Multicentre randomised trial

Cont Lens Anterior Eye. 2018 Jun;41(3):258-262. doi: 10.1016/j.clae.2017.12.012. Epub 2017 Dec 16.

Abstract

Purpose: To determine if the discontinuation of commercially-available simultaneous vision Multifocal Soft Contact Lenses is independent from the multifocal design. To determine causes for discontinuation and psychosocial factors involved.

Methods: Multicentre single-blinded randomised controlled trial with external blinded evaluation for a three months follow-up period for three intervention groups. 150 single-vision soft wearers were randomly assigned a spherical near centred lens (S-CN), distance centred lens (CD) or aspherical near centred lens (A-CN). Cases of discontinuation, anxiety and quality of life were measured at one week and one month.

Results: 120 females and 30 males were included with an age range of 40-62 (48.79 ± 5.23). At one month, the S-CN design had a statistically significant higher risk of discontinuation than the other two OR: 6.12 (95%CI 2.5-14.9). Twenty-eight subjects discontinued wearing S-CN at first week (56%), while discontinuation of CD and A-CD were 15 (30%) and 11 (22%), with a statistically significant difference between S-CN design and the other two (p = 0.001). There were not statistically significant differences when direct comparison between discontinuation of CD and A-CN was made (p = 0.36). Thirty-two percent discontinued the use because of poor distance vision and 28% because of both poor distance and near vision. Psychosocial factors were not statistically significant.

Conclusions: Discontinuation of Multifocal Soft Contact Lenses is dependent on the design. Most common cause for discontinuation is poor distance vision. Psychosocial factors do not impact on discontinuation rates.

Keywords: Discontinuation; Multifocal design; Psychosocial factors; Quality of life; Simultaneous vision.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial

MeSH terms

  • Adult
  • Aged
  • Contact Lenses, Hydrophilic*
  • Equipment Design
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Patient Satisfaction*
  • Prosthesis Fitting / methods*
  • Quality of Life*
  • Refraction, Ocular / physiology*
  • Refractive Errors / physiopathology
  • Refractive Errors / therapy*
  • Single-Blind Method