Is external cervical orthotic bracing necessary after posterior atlantoaxial fusion with modern instrumentation: meta-analysis and review of literature

World Neurosurg. 2013 Feb;79(2):369-74.e1-12. doi: 10.1016/j.wneu.2012.03.022. Epub 2012 Apr 3.

Abstract

Background: No guidelines exist regarding external cervical orthoses (ECO) after atlantoaxial fusion. We reviewed published series describing C1-2 posterior instrumented fusions with screw-rod constructs (SRC) or transarticular screws (TAS) and compared rates of fusion with and without postoperative ECO.

Methods: Online databases were searched for English-language articles between 1986 and April 2011 describing ECO use after posterior atlantoaxial instrumentation with SRC or TAS. Eighteen studies describing 947 patients who had SRC (± ECO: 254 of 693 patients), and 33 studies describing 1424 patients with TAS (± ECO: 525 of 899 patients) met inclusion criteria. Meta-analysis techniques were applied to estimate rates of fusion with and without ECO use.

Results: All studies provided class III evidence, and no studies directly compared outcomes with or without ECO use. There was no significant difference in the proportion of patients who achieved successful fusion between patients treated with ECO and without ECO for SRC or TAS patients. Point estimates and 95% confidence intervals (CI) for rates of fusion ± ECO were 97.4% (CI: 95.2% to 98.6%) versus 97.9% (CI: 93.6% to 99.3%) for SRC and 93.6% (CI: 90.7% to 95.6%) versus 95.3% (CI: 90.8% to 97.7%) for TAS. There was no correlation between duration of ECO treatment and fusion (dose effect).

Conclusions: After C1-2 fusion with modern instrumentation, ECO may be unnecessary (class III). Some centers recommend ECO use with patients with softer bone quality (class IV). Prospective, randomized studies with validated radiographic and clinical outcome metrics are necessary to determine the utility of ECO after C1-2 fusion and its impact on patient comfort and cost.

Publication types

  • Meta-Analysis
  • Review

MeSH terms

  • Atlanto-Axial Joint / surgery*
  • Braces*
  • Humans
  • Spinal Fusion / instrumentation*
  • Spinal Fusion / rehabilitation