Morphologic findings of the aortic homograft implanted in the tricuspid position

Ann Thorac Surg. 2009 Jun;87(6):1951-2. doi: 10.1016/j.athoracsur.2008.10.050.

Abstract

We present histologic findings of the aortic homograft mounted in a woven Dacron (C.R. Bard, Haverhill, PA) tube, which had been in the tricuspid position for 68 months in a patient with Ebstein anomaly. Although the layered architecture of leaflets was relatively well preserved, prominent calcification was observed in the sinus wall that had been in direct contact with the surrounding fabric. This sinus stiffness might have contributed to worsening of the valvar function.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Aortic Valve / pathology
  • Aortic Valve / transplantation
  • Ebstein Anomaly / surgery*
  • Female
  • Heart Valve Prosthesis*
  • Humans
  • Tricuspid Valve / surgery*