We describe the first reported case of pneumonia due to Legionella pneumophila serogroup 12 in the UK. This hospital-associated infection occurred in an immuno-incompetent patient and coincided with a change in character of the local environmental strains of legionellas. The patient produced a serological response both to her own isolate and to L. pneumophila serogroups 1-6. Thus serodiagnosis was attainable using the usual screening antigens.