NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM5280913 Query DataSets for GSM5280913
Status Public on May 04, 2021
Title RNA_049v09001901
Sample type SRA
 
Source name Plasma
Organism human blood metagenome
Characteristics tissue: Plasma
cohort_number: 1
batches_per_cohort_per_source: No
geographical_location: USA: Cleveland, Ohio
cd4 count: 960
cd8 count: 1640
cd4: cd8 t cell ratio: 0.585365853658537
hiv_infected?: Yes
on_art?: Yes
subject_classification: Responder (>3yr on ART)
Extracted molecule total RNA
Extraction protocol sorted cells: RNA was extracted from sorted cells lysed in RNAzol RT (MRC Inc., OH, USA), according to the manufacturer’s instructions. Briefly, 0.4 volume of sterile water was added to each lysate to allow aqueous and organic phase separation. Total RNA was then extracted from the aqueous phase by isopropanol precipitation. RNA pellets were washed with 70% ethanol and resuspended in sterile water. Extracted RNA was stored at -80°C until preparation of mRNA libraries. RNA yield and integrity were verified by microelectrophoresis using the High Sensitivity RNA ScreenTape Kit (Agilent) on the 2200 TapeStation system (Agilent).
plasma: Circulating total RNA and DNA were isolated from frozen plasma using RNAzolBD (MRC) according to the manufacturer’s recommendations.
sorted cells: mRNA libraries were constructed as described previously (Sandler et al., 2014) using the NEBNext Ultra RNA library preparation kit. Polyadenylated transcripts were purified with oligo-dT magnetic beads, fragmented, reverse transcribed using random hexamers and incorporated into barcoded cDNA libraries based on the Illumina TruSeq platform. Libraries were validated by microelectrophoresis on a 2100 Bioanalyzer system (Agilent), quantified with Kapa Library Quantification Kits (Roche), pooled and clustered on Illumina TruSeq v2 flow cells. Clustered flow cells were sequenced in 2x75 base paired-end runs on Illumina HiSeq 2000 and HiSeq 4000.
plasma: RNA fragmentation and reverse transcription using random hexamers, the obtained transcripts, as well as the isolated plasma DNA, were individually incorporated into barcoded cDNA libraries on the basis of the Illumina TruSeq platform. Libraries were validated by microelectrophoresis on a 2100 Bioanalyzer system (Agilent), quantified using Kapa Library Quantification Kits (Roche), pooled and clustered on Illumina patterned flow cells. Clustered flow cells were sequenced on an Illumina HiSeq 4000 in 75-base paired reads. To control for contamination, four water samples were processed along with plasma samples from nucleic acids extraction through sequencing.
 
Library strategy OTHER
Library source transcriptomic
Library selection other
Instrument model Illumina HiSeq 4000
 
Description PathSeq
Cleveland_PathSeq_TPM.xlsx
Data processing Library strategy: PathSeq metagenome
sorted cells/plasma: Raw sequencing reads were trimmed off adapter sequence contaminants using Trimmomatic v. 0.36
sorted cells/plasma: Mapped onto the Refseq Grch38 of the human genome using the STAR RNA-Seq aligner (version 2.5.3a)
sorted cells: Gene abundance was then estimated by counting using HTSeq (version 0.9.1)
sorted cells: Transcript counts were then normalized by TMM (Trimmed Mean of M-values by correcting for the library size
plasma: Unaligned paired-end reads were then assembled into contigs using Trinity
plasma: Trinity contigs were then aligned against HG38 again to further remove host-derived sequences with BLAST+. Trinity contigs that aligned to non-reference human sequences in the NCBI nucleotide database were also removed
plasma: Remaining contigs were then aligned against the NCBI nucleotide database and quantified with Salmon
plasma: Taxonomic information was assigned for each contig and transcripts per million (TPM) values were collapsed at the species level for each sample. TPM are normalized for sequencing read depth and length for each sample, allowing for a more accurate comparisons between proportion of reads mapping to the same gene in various samples
Genome_build: Human (Refseq Grch38) and Non-human (NCBI nucleotide database and quantified with Salmon)
Supplementary_files_format_and_content: xlsx data matrix files with normalized read counts (sorted cells; sample by transcript) or TPM (plasma; sample by species abundance)
 
Submission date May 04, 2021
Last update date May 06, 2021
Contact name Rafick-Pierre Sekaly
E-mail(s) rafick.sekaly@emory.edu
Organization name Emory University
Department Pathology
Lab Sekaly Lab
Street address 1750 Haygood Drive
City Atlanta
State/province GA
ZIP/Postal code 30322
Country USA
 
Platform ID GPL30076
Series (1)
GSE172557 Changes in bacterial diversity and composition detected in plasma determine immunological outcome in HIV+ persons initiating antiretroviral therapy
Relations
BioSample SAMN19011438
SRA SRX10770313

Supplementary data files not provided
SRA Run SelectorHelp
Raw data are available in SRA
Processed data are available on Series record

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap