NCBI Bookshelf. A service of the National Library of Medicine, National Institutes of Health.
Database of Abstracts of Reviews of Effects (DARE): Quality-assessed Reviews [Internet]. York (UK): Centre for Reviews and Dissemination (UK); 1995-.
Database of Abstracts of Reviews of Effects (DARE): Quality-assessed Reviews [Internet].
Show detailsCRD summary
This review concluded that magnetic resonance was the preferred first-line imaging modality for evaluating liver metastases in previously untreated patients with colorectal cancer; 18fluorodeoxyglucose positron emission tomography could be used as the second-line modality. Limitations in the available data and analyses mean that these conclusions should be interpreted cautiously.
Authors' objectives
To assess the diagnostic accuracy of computed tomography (CT), magnetic resonance imaging (MRI), 18fluorodeoxyglucose positron emission tomography (18FDG-PET) and 18FDG-PET/CT for the detection of liver metastases in patients with previously untreated colorectal cancer.
Searching
MEDLINE, EMBASE, CINAHL, Web of Science and the Cochrane Database of Systematic Reviews were searched from January 1990 to January 2010. Search strategies were reported in an appendix.
Study selection
Prospective studies that assessed the accuracy of CT, MRI, 18FDG-PET, or 18FDG-PET/CT for identifying liver metastases in patients with histologically proven primary colorectal cancer were eligible for inclusion. Included studies had to have at least 10 participants, use intra-operative findings, histological examination, or follow-up as the reference standard, and report sufficient data to calculate sensitivity and specificity. Studies were excluded if they reported combined data for different imaging modalities or if the data for the individual modalities could not be extracted separately.
Studies evaluated both patients with suspected and known metastases. The mean age of study participants was 61.4 years (range 20 to 93 years); just over half were male. Histological examination was the most frequent reference standard, used in all but two studies; studies also used intra-operative palpitation, intra-operative ultrasound and follow-up. Full technical details of imaging modalities used were reported in a supplementary online appendix (see URL for Additional Data). CT studies used single-section or multi-section helical scanning. All but one of the MRI studies used contrast-enhanced techniques. All 18FDG-PET studies used whole-body scanners.
Two reviewers independently selected studies for the review. Any disagreements were resolved by consensus.
Assessment of study quality
Two reviewers independently assessed study quality, using a modified, ten-item version of QUADAS (Quality Assessment of Diagnostic Accuracy Studies); any disagreements were resolved by consensus. Items assessed were: use of an appropriate patient spectrum; selection of participants; execution of the index test and reference standard; evaluation of the index test and reference standard; availability of clinical information; differential and partial verification biases; and independence of the reference standard.
Data extraction
Two reviewers extracted data to populate 2x2 contingency tables (numbers of true positive, false negative, false positive, and true negative imaging test results), on a per-lesion and per-patient basis. Any disagreements were resolved by consensus. Data were used to calculate per-lesion sensitivity and per-patient sensitivity and specificity.
Methods of synthesis
Studies were grouped by imaging modality. Summary estimates of per-patient sensitivity and specificity and per-lesion sensitivity, with 95% confidence intervals (CIs), were calculated for each modality. Between-study heterogeneity was quantified using I2. Where I2 was below 25%, a fixed-effect model was used to generate summary estimates; where I2 was 25% or over, a random-effects model was used. The z-test was used to assess differences between imaging modalities.
The following subgroup analyses were conducted for per-lesion data: comparisons between CT and MRI for the detection of lesions under 10mm versus 10mm or more (head-to head comparisons only); studies performed before and after January 2004; studies using single-section CT versus studies using multi-section CT; CT performed in the portal phase alone versus CT performed in both arterial and portal phases; comparisons between un-enhanced MRI versus MRI using different contrast agents.
Publication bias was assessed using funnel plots and the Egger regression test, for per-lesion data.
Results of the review
Thirty-nine studies (n=3,391 patients) were included in the review. Study quality was variable; the most frequently failed QUADAS criteria were avoidance of differential verification bias, and adequate execution and evaluation of the reference standard. The availability of clinical data was poorly reported.
Computed tomography (CT): The per-lesion estimate of diagnostic sensitivity (38 data sets) for liver metastases was 74.4% (95% CI 68.7 to 79.3; I2=70.9%). The per-patient estimate (nine data sets) of sensitivity was 83.6% (95% CI 66.9 to 92.8; I2=92.9%) and specificity was 94.9% (95% CI 92.9 to 96.3; I2=52.5%).
Magnetic resonance imaging (MRI): The per-lesion estimate of sensitivity (61 data sets) was 80.3% (95% CI 74.6 to 85.0; I2=83.4%). The per-patient estimate (six data sets) of sensitivity was 88.2% (95% CI 64.8 to 96.8; I2=43.3%) and specificity was 92.5% (95% CI 89.5 to 94.6; I2=61.8%).
18Fluorodeoxyglucose positron emission tomography (18FDG-PET): The per-lesion estimate of sensitivity (eight data sets) was 81.4% (95% CI 66.5 to 90.6; I2=86.4%). The per-patient estimate (six data sets) of sensitivity was 94.1% (95% CI 91.6 to 95.9; I2=0%) and specificity was 95.7% (95% CI 92.7 to 97.6; I2=0%).
18FDG-PET/CT: The per-lesion estimate of sensitivity (one data set) was 66.2% (95% CI 54.5 to 76.2). The per-patient estimate (three data sets) of sensitivity was 96.5% (95% CI 94.2 to 97.9) and specificity was 97.2% (95% CI 92.8 to 99.0).
Comparisons between imaging modalities: The per-patient sensitivity of CT was lower than that of 18FDG-PET; all other estimates were comparable.
Subgroup analyses: For lesions smaller than 10mm, the sensitivity of MRI was higher than that of CT. The sensitivity of MRI increased significantly after January 2004. No other subgroup analyses showed significant differences between groups.
There was no evidence of publication bias.
Authors' conclusions
MRI was the preferred first-line imaging modality for evaluating liver metastases in previously untreated patients with colorectal cancer. 18FDG-PET could be used as the second-line modality. The role of 18FDG-PET/CT was unclear due to the small number of studies.
CRD commentary
The review reported a clear research question. Inclusion criteria were defined for participants, index test, reference standard, outcomes and study design. A number of sources were searched for relevant studies; search strategies were reported in full. Measures to minimise error and/or bias were applied throughout the review process.
The methodological quality of included studies was assessed and findings reported. The calculation of pooled estimates of sensitivity and specificity was questionable, given the apparent between-study heterogeneity. The authors' conclusions broadly reflected the data presented. However, the overall performance of MRI and 18FDG-PET appeared equivalent and no assessment was made of the performance of 18FDG-PET for the detection of smaller lesions (the basis for the authors' differentiation between the two modalities).
The limited data on 18FDG-PET and weaknesses in the analysis mean that the authors' conclusions should be interpreted cautiously.
Implications of the review for practice and research
Practice: The authors did not specify any recommendations for practice.
Research: The authors provided detailed recommendations for the reporting of study design characteristics and presentation of data in future studies, in an on-line appendix.
Funding
Not stated
Bibliographic details
Niekel MC, Bipat S, Stoker J. Diagnostic imaging of colorectal liver metastases with CT, MR imaging, FDG PET, and/or FDG PET/CT: a meta-analysis of prospective studies including patients who have not previously undergone treatment. Radiology 2010; 257(3): 674-684. [PubMed: 20829538]
Original Paper URL
Indexing Status
Subject indexing assigned by NLM
MeSH
Colorectal Neoplasms /pathology; Contrast Media /diagnostic use; Fluorodeoxyglucose F18 /diagnostic use; Humans; Liver Neoplasms /radiography /radionuclide imaging /secondary; Magnetic Resonance Imaging; Positron-Emission Tomography; Prospective Studies; Radiopharmaceuticals /diagnostic use; Sensitivity and Specificity; Tomography, X-Ray Computed
AccessionNumber
Database entry date
14/09/2011
Record Status
This is a critical abstract of a systematic review that meets the criteria for inclusion on DARE. Each critical abstract contains a brief summary of the review methods, results and conclusions followed by a detailed critical assessment on the reliability of the review and the conclusions drawn.
- CRD summary
- Authors' objectives
- Searching
- Study selection
- Assessment of study quality
- Data extraction
- Methods of synthesis
- Results of the review
- Authors' conclusions
- CRD commentary
- Implications of the review for practice and research
- Funding
- Bibliographic details
- Original Paper URL
- Indexing Status
- MeSH
- AccessionNumber
- Database entry date
- Record Status
- Colorectal liver metastases: CT, MR imaging, and PET for diagnosis--meta-analysis.[Radiology. 2005]Colorectal liver metastases: CT, MR imaging, and PET for diagnosis--meta-analysis.Bipat S, van Leeuwen MS, Comans EF, Pijl ME, Bossuyt PM, Zwinderman AH, Stoker J. Radiology. 2005 Oct; 237(1):123-31. Epub 2005 Aug 11.
- Imaging of colorectal cancer liver metastases using contrast-enhanced US, multidetector CT, MRI, and FDG PET/CT: a meta-analysis.[Acta Radiol. 2021]Imaging of colorectal cancer liver metastases using contrast-enhanced US, multidetector CT, MRI, and FDG PET/CT: a meta-analysis.Tsili AC, Alexiou G, Naka C, Argyropoulou MI. Acta Radiol. 2021 Mar; 62(3):302-312. Epub 2020 Jun 6.
- Contrast-enhanced FDG-PET/CT vs. SPIO-enhanced MRI vs. FDG-PET vs. CT in patients with liver metastases from colorectal cancer: a prospective study with intraoperative confirmation.[Acta Radiol. 2007]Contrast-enhanced FDG-PET/CT vs. SPIO-enhanced MRI vs. FDG-PET vs. CT in patients with liver metastases from colorectal cancer: a prospective study with intraoperative confirmation.Rappeport ED, Loft A, Berthelsen AK, von der Recke P, Larsen PN, Mogensen AM, Wettergren A, Rasmussen A, Hillingsoe J, Kirkegaard P, et al. Acta Radiol. 2007 May; 48(4):369-78.
- Review Preoperative imaging of colorectal liver metastases after neoadjuvant chemotherapy: a meta-analysis.[Ann Surg Oncol. 2012]Review Preoperative imaging of colorectal liver metastases after neoadjuvant chemotherapy: a meta-analysis.van Kessel CS, Buckens CF, van den Bosch MA, van Leeuwen MS, van Hillegersberg R, Verkooijen HM. Ann Surg Oncol. 2012 Sep; 19(9):2805-13. Epub 2012 Mar 7.
- Review The diagnostic performance of (18)F-FDG PET/CT, CT and MRI in the treatment evaluation of ablation therapy for colorectal liver metastases: A systematic review and meta-analysis.[Surg Oncol. 2017]Review The diagnostic performance of (18)F-FDG PET/CT, CT and MRI in the treatment evaluation of ablation therapy for colorectal liver metastases: A systematic review and meta-analysis.Samim M, Molenaar IQ, Seesing MFJ, van Rossum PSN, van den Bosch MAAJ, Ruers TJM, Borel Rinkes IHM, van Hillegersberg R, Lam MGEH, Verkooijen HM. Surg Oncol. 2017 Mar; 26(1):37-45. Epub 2016 Dec 29.
- Diagnostic imaging of colorectal liver metastases with CT, MR imaging, FDG PET, ...Diagnostic imaging of colorectal liver metastases with CT, MR imaging, FDG PET, and/or FDG PET/CT: a meta-analysis of prospective studies including patients who have not previously undergone treatment - Database of Abstracts of Reviews of Effects (DARE): Quality-assessed Reviews
- DDHD1 DDHD domain containing 1 [Homo sapiens]DDHD1 DDHD domain containing 1 [Homo sapiens]Gene ID:80821Gene
- Gene Links for GEO Profiles (Select 69892450) (1)Gene
- Homologene neighbors for GEO Profiles (Select 69892450) (0)GEO Profiles
- BMP4 bone morphogenetic protein 4 [Homo sapiens]BMP4 bone morphogenetic protein 4 [Homo sapiens]Gene ID:652Gene
Your browsing activity is empty.
Activity recording is turned off.
See more...