NCBI Bookshelf. A service of the National Library of Medicine, National Institutes of Health.
Database of Abstracts of Reviews of Effects (DARE): Quality-assessed Reviews [Internet]. York (UK): Centre for Reviews and Dissemination (UK); 1995-.
Database of Abstracts of Reviews of Effects (DARE): Quality-assessed Reviews [Internet].
Show detailsAuthors' objectives
To compare the efficacy and safety of routine electronic foetal monitoring of labour with intermittent auscultation.
Searching
MEDLINE was searched from 1966 to 1994 and references in published reports were obtained. Experts in the field and from the Cochrane Collaboration were contacted for unpublished data.
Study selection
Study designs of evaluations included in the review
Randomised controlled trials (RCTs) were included.
Specific interventions included in the review
Electronic foetal monitoring, and auscultation. Intermittent electronic foetal monitoring, intermittent Doppler ultrasound, and two forms of auscultation were also included in some trials, but were not directly assessed in this review.
Reference standard test against which the new test was compared
The review did not include any diagnostic accuracy studies that compared the performance of the index test with a reference standard of diagnosis.
Participants included in the review
Pregnant women and their infants in both high- and low-risk pregnancies, from 10 clinical centres in the United States, Europe, Australia and Africa, were included.
Outcomes assessed in the review
The outcomes assessed were Apgar score, neonatal seizures, neonatal intensive care unit admissions, stillbirths, neonatal deaths, Caesarean delivery, operative vaginal delivery.
How were decisions on the relevance of primary studies made?
The authors do not state how the papers were selected for the review, or how many of the authors performed the selection.
Assessment of study quality
Study quality was assessed on 13 factors (based on 22 previously developed weighted criteria) and a percentage quality score was calculated. A single reviewer assessed study quality.
Data extraction
The data were abstracted by one researcher and their accuracy independently confirmed by another. Authors were contacted for data not presented in published reports.
Methods of synthesis
How were the studies combined?
Meta-analysis was performed, using relative risks (RRs) calculated as: (1) the combined risk estimate for each of eight outcomes (1-minute Apgar score < 7, 1-minute Apgar score < 4, neonatal seizures, neonatal intensive care unit admissions, still births, neonatal deaths, Caesarean delivery, and operative vaginal delivery); (2) the total operative deliveries (Caesarean and operative vaginal delivery); and (3) perinatal deaths (foetal and neonatal). Where adjustments for multiple comparisons were made, original data of neonatal seizure were pooled rather than risk estimates, owing to the lack of data. For the other outcomes, risk estimates were weighted by sample size and then weighted to get an overall estimate.
A cumulative meta-analysis was also performed, according to increasing quality score and study size. A random-effects model was used for outcomes in which significant heterogeneity was present.
How were differences between studies investigated?
A test for heterogeneity was performed. Subgroup analyses were undertaken for five groups of studies: all studies comparing routine electronic foetal monitoring with auscultation; studies in which electronic foetal monitoring was performed without foetal scalp sampling; studies in which electronic foetal monitoring was performed with foetal scalp sampling; studies with low- medium- and high-quality scores; United States and non-United States studies.
Results of the review
Twelve RCTs (58,855 pregnant women, 59,324 infants) were included. Nine trials (18,561 pregnant women, 18,695 infants) compared continuous electronic foetal monitoring with auscultation. Three trials (40,294 pregnant women, 40,629 infants) compared continuous electronic foetal monitoring with alternative approaches (intermittent electronic foetal monitoring, intermittent Doppler ultrasound, and two forms of auscultation).
A statistically significant decrease was associated with routine electronic foetal monitoring for a 1-minute Apgar score of less than 4 (RR 0.82, 95% confidence interval, CI: 0.65, 0.98), and neonatal seizures (RR 0.5, 95% CI: 0.30, 0.82). Monitoring based on the Apgar score was only significant for non-United States studies, whilst monitoring of neonatal seizures was only significant for high-quality studies. A statistically significant increase associated with the use of electronic foetal monitoring was found in the Caesarean delivery rate (RR 1.21, 95% CI: 1.04, 1.39) and total operative delivery (RR 1.23, 95% CI: 1.15, 1.31). The risk of Caesarean delivery was greatest in low-risk pregnancies. No significant differences were observed in 1-minute Apgar score of less than 7, rate of admissions to neonatal intensive care units, and perinatal death. Only 3 of the 12 studies scored more than 60% on quality score. Although all studies described the regimens, provided well-defined end points, used appropriate analyses and reported complications, few stated clear hypotheses, provided power calculations, implemented adequate blinding or undertook subgroup analyses.
Authors' conclusions
The only clinically significant benefit from the use of routine electronic foetal monitoring was in the reduction of neonatal seizures. Because of the increase in Caesarean and operative vaginal deliveries, the long-term benefit of this reduction (which is unclear) must be evaluated in the decision reached jointly by the pregnant woman and her clinician before their decision on the use of electronic foetal monitoring or intermittent auscultation during labour. Future RCTs should focus on clearly specified clinical questions: (1) Which groups might benefit most from intensive intrapartum surveillance? (2) What are the essential or desirable elements of this technique? (3) What is the long-term follow-up of children in the 12 studies already conducted?
CRD commentary
This was a very thorough review, with a good discussion of the limitations and benefits of meta-analysis for this subject. The authors objectives only included the use of published trials, which could bias the results. However, the review details revealed that unpublished studies were searched for, but none were found.
Implications of the review for practice and research
There appears to be no justification for the routine use of continuous electronic foetal monitoring during normal labour. The authors suggest that a decision regrading monitoring during labour should be reached jointly by the pregnant woman and her clinician, taking into account the research evidence. This is in line with current policy on provision of choice about interventions during pregnancy and childbirth.
Bibliographic details
Thacker S B, Stroup D F, Peterson H B. Efficacy and safety of intrapartum electronic fetal monitoring: an update. Obstetrics and Gynecology 1995; 86(4 Part 1): 613-620. [PubMed: 7675390]
Other publications of related interest
1. MIDIRS/CRD. Listening to your baby's heartbeat during labour (Informed Choice leaflet for women). 2. MIDIRS/CRD. Fetal heart rate monitoring in labour. (Informed Choice leaflet for health care professionals).
These leaflets are available from MIDIRS, 9 Elmdale Road, Clifton, Bristol BS8 1SL, UK.
Indexing Status
Subject indexing assigned by NLM
MeSH
Female; Fetal Monitoring /adverse effects /methods; Humans; Labor, Obstetric; Pregnancy; Randomized Controlled Trials as Topic
AccessionNumber
Database entry date
31/07/1996
Record Status
This is a critical abstract of a systematic review that meets the criteria for inclusion on DARE. Each critical abstract contains a brief summary of the review methods, results and conclusions followed by a detailed critical assessment on the reliability of the review and the conclusions drawn.
- Authors' objectives
- Searching
- Study selection
- Assessment of study quality
- Data extraction
- Methods of synthesis
- Results of the review
- Authors' conclusions
- CRD commentary
- Implications of the review for practice and research
- Bibliographic details
- Other publications of related interest
- Indexing Status
- MeSH
- AccessionNumber
- Database entry date
- Record Status
- Review Continuous electronic heart rate monitoring for fetal assessment during labor.[Cochrane Database Syst Rev. 2001]Review Continuous electronic heart rate monitoring for fetal assessment during labor.Thacker SB, Stroup D, Chang M. Cochrane Database Syst Rev. 2001; (2):CD000063.
- Review WITHDRAWN: Continuous electronic heart rate monitoring for fetal assessment during labor.[Cochrane Database Syst Rev. 2007]Review WITHDRAWN: Continuous electronic heart rate monitoring for fetal assessment during labor.Thacker SB, Stroup D, Chang M. Cochrane Database Syst Rev. 2007 Jul 18; 2006(3):CD000063. Epub 2007 Jul 18.
- Review Continuous electronic heart rate monitoring for fetal assessment during labor.[Cochrane Database Syst Rev. 2000]Review Continuous electronic heart rate monitoring for fetal assessment during labor.Thacker SB, Stroup DF. Cochrane Database Syst Rev. 2000; (2):CD000063.
- A randomized trial of intrapartum electronic fetal heart rate monitoring versus intermittent auscultation.[Obstet Gynecol. 1993]A randomized trial of intrapartum electronic fetal heart rate monitoring versus intermittent auscultation.Vintzileos AM, Antsaklis A, Varvarigos I, Papas C, Sofatzis I, Montgomery JT. Obstet Gynecol. 1993 Jun; 81(6):899-907.
- Review Intrapartum electronic fetal heart rate monitoring and the prevention of perinatal brain injury.[Obstet Gynecol. 2006]Review Intrapartum electronic fetal heart rate monitoring and the prevention of perinatal brain injury.Graham EM, Petersen SM, Christo DK, Fox HE. Obstet Gynecol. 2006 Sep; 108(3 Pt 1):656-66.
- Efficacy and safety of intrapartum electronic fetal monitoring: an update - Data...Efficacy and safety of intrapartum electronic fetal monitoring: an update - Database of Abstracts of Reviews of Effects (DARE): Quality-assessed Reviews
- OsteopontinOsteopontinA negatively-charged extracellular matrix protein that plays a role in the regulation of BONE metabolism and a variety of other biological functions. Cell signaling by osteopo...<br/>Year introduced: 2007(1987)MeSH
- AGER advanced glycosylation end-product specific receptor [Bos taurus]AGER advanced glycosylation end-product specific receptor [Bos taurus]Gene ID:280986Gene
- Ptprs protein tyrosine phosphatase, receptor type, S [Rattus norvegicus]Ptprs protein tyrosine phosphatase, receptor type, S [Rattus norvegicus]Gene ID:25529Gene
Your browsing activity is empty.
Activity recording is turned off.
See more...