This book is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) ( http://creativecommons.org/licenses/by-nc-nd/4.0/ ), which permits others to distribute the work, provided that the article is not altered or used commercially. You are not required to obtain permission to distribute this article, provided that you credit the author and journal.
NCBI Bookshelf. A service of the National Library of Medicine, National Institutes of Health.
StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024 Jan-.
StatPearls [Internet].
Show detailsContinuing Education Activity
Point of care optic nerve sheath ultrasound (ONSUS) is a bedside practice that can be used to evaluate for increased intracranial pressure. Systematic review and meta-analysis have shown that ONSD of more than 5.00 to 5.70 mm has a concurrent ICP value above 20 mm Hg. Systematic review and meta-analysis showed a mean ONSD in the included studies of 5.82 mm. ONSD reacts to ICP in real-time. Within the effective range, the chances of plastic deformation and over-distention of the ONS are minimal. It is a very useful adjunct to other standard diagnostic modalities. This activity reviews indications and limitations and describes the procedure. It outlines applicable uses for unstable patients in the emergency room, intensive care unit, and remote environments.
Objectives:
- Describe the eye anatomy as it relates to increased intracranial pressure.
- Summarize the ONSUS procedure, including its contraindications.
- Explain the measurements of the optic nerve and the associated clinical significance.
- Describe the clinical significance of optic nerve sheath ultrasound (ONSUS) in an austere environment and how it could provide better patient care by an interprofessional team.
Introduction
The use of point-of-care ultrasound (POCUS) has expanded considerably over the past two decades allowing for enhanced and swift evaluations, rapid triage, improved diagnostic capabilities in austere situations, and real-time assessment of focused clinical questions in critically ill patients in the intensive care unit (ICU).[1] Emergency medicine physicians have led the way in establishing and educating bedside use of ultrasound. In 2001, the American College of Emergency Physicians (ACEP) published the first Emergency Ultrasound Guidelines to clarify the primary indications, the scope of practice, training, and continuing education regarding the use of emergency ultrasound.[2]
These guidelines have continued to expand alongside the ever-growing use of ultrasound. They have been adopted by several other specialties, especially in applying “procedural ultrasound” to assist in real-time guidance of vascular access, peripheral nerve blockade, and pre-surgical evaluations.[3][4]
The main difference between POCUS and dedicated ultrasound exams is the ability to rapidly answer a focused clinical question, facilitate serial examinations in clinical deterioration, or guide a bedside procedure rather than provide a detailed report with the grading of pathology.[2][5] With small, portable ultrasound models becoming available, advanced diagnostics are becoming more accessible in remote environments and on the battlefield. Physicians and advanced paramedical providers in these settings are becoming trained to perform extended focused assessment with sonography in trauma (eFAST), optic nerve sheath ultrasound (ONSUS) for the evaluation of intracranial hypertension, inferior vena cava collapsibility assessments for the evaluation of volume status, and countless other examples of image-guided procedures.[6][7] This article will focus on optic nerve sheath ultrasound for the diagnosis, monitoring, and management of elevated intracranial pressure (ICP).
Anatomy and Physiology
The eye is an ideal configuration for ultrasound imaging as it is superficial with well-demarcated fluid-filled structures that serve as an excellent medium for ultrasound beam transduction. At least a basic understanding of ocular anatomy is required to perform an ONSUS. Identifying anterior structures will increase success in measuring the optic nerve sheath in the correct plane.
The eyeball rests in a membranous sac called the Tenon capsule, surrounded by periocular fat, soft tissue, and the orbital walls. It attaches via the corneoscleral junction and the optic nerve, with extraocular muscle tendons piercing the Tenon sac, inserting into the sclera, and allowing for eyeball mobility on multiple axes. Two fluid-filled structures that require identification in the study include the anterior chamber (AC) and posterior chamber (PC), which are separated by the lens and both harbor anechoic fluid. Posterior to the PC is the retina with a hyperechoic nervous membrane.[8]
Posterior to the retina and optic disc, one can identify the optic nerve by its anechoic core, flanked by a hyperechoic sheath on the medial and lateral borders in the transverse plane. The optic nerve can be thought of as an outpouching of intact brain tissue with the intraorbital component fully encapsulated by dura, arachnoid, and pia matter, allowing the optic nerve sheath to transmit cerebral spinal fluid and fluctuate in size based on changes in intracranial pressure.[9][10] The meningeal cover of the optic nerve is the continuation of the dural and subarachnoid space.[11] The bulbous portion of the optic nerve, approximately 3 mm posterior to the globe, appears to be the most distensible and sensitive to changes in ICP based on in-vivo models of elevated ICP and artificial creations of elevated ICP in cadaveric models.[9][12]
The upper limit of the normal ONSD includes:
- 4 mm in infants.
- 5 mm in children.
- 5 mm in adults.
ONSD shows linear increment till 7.5 mm, after which it plateaus off.[13]
Indications
Ocular ultrasound can be performed for various reasons, including vision loss, headache, and trauma. It can be very beneficial in identifying or excluding retinal detachment, foreign bodies, lens dislocation, vitreous hemorrhage, and other superficial abnormalities that can cause loss of eyesight. ONSUS is usually performed in the setting of suspected or confirmed traumatic brain injury (TBI), intracranial hypertension, or optic neuritis.[14] ONSUS is non-invasive and avoids the risk of infection, hemorrhage, or ionizing radiation that are inevitable with intracranial monitors and computed tomography (CT).[15]
ONSUS can also be used to help “rule out” elevated ICP in non-acute trauma settings, such as troubleshooting a malfunctioning intraventricular device, before or following lumbar punctures, or while evaluating the safety of neuraxial anesthesia in patients with a previous history of elevated ICP. It should be emphasized that these readings should be evaluated in the overall clinical context, as such applications are not well studied or validated.[16][17][18][19][20]
ONSD is currently considered the best non-invasive modality for dynamic estimation of ICP.[21] POCUS measurements have shown ONSD to be significantly correlating with ICP.[22] ICP can be calculated using the formula ONSD: nICPONSD = 5.00 × ONSD − 13.92 mmHg.[23] This is a holy grail in assessing critical patients in whom invasive ICP monitoring is either unavailable or is contraindicated.[21] This has been found helpful in the evaluation of the following cohorts of patients:
Contraindications
Surface ultrasound remains a safe modality with little to no risk to adult patients. However, if an open globe injury is suspected, there is potential for further ocular injury, and the study should not proceed without consultation or assistance from an ophthalmologist.[33][34]
Equipment
The advantage of ONSUS is that it can be performed with most ultrasound equipment that is abundantly available in emergency departments and ICUs throughout the United States. There are commercially available high-frequency ocular ultrasound units designed for dedicated studies of the eye, but most conventional ultrasound units with a high frequency (7 to 10 MHz or higher) linear array probes are sufficient to visualize the optic nerve with the closed eye technique.[35][36] Additional equipment may include a clear sterile intravenous catheter adhesive to create a barrier and ultrasound gel as a conduction medium.
Personnel
Typically, ONSUS can be performed by an individual and requires no additional assistance in patient positioning. Depending on space constraints, it can be useful to have an assistant familiar with ultrasound to capture images, adjust depth, gain, and other functions to optimize imaging.
Preparation
Awake and alert patients should be briefed on the procedure. Obtunded, intubated, or heavily sedated patients should have a gross eye evaluation for signs and symptoms of globe rupture or hyphema. If there is evidence of globe rupture, including visible conjunctival or scleral defect, severe chemosis, 360-degree conjunctival hemorrhage, hypotony, or total hyphema, the procedure should be aborted to avoid further herniation of intraocular contents, and an ophthalmologist should be consulted.[37][38]
It can be beneficial to instruct awake patients to "look ahead" with a closed eye or to examine the eye orientation in obtunded patients before the procedure to orient the ultrasound beam in the transverse plane and avoid oblique slices of the optic nerve. Some practitioners will apply petroleum jelly or ophthalmic ointment to the eyes to avoid air trapping before applying a clear plastic adhesive dressing. Ultrasound gel should be applied liberally to the adhesive before scanning.[39]
The patient's position should be dictated by comfort and ease of examination but will typically be done in the supine to 30 degrees "head up" position. Although theoretical concerns may exist for changes in ICP and ocular nerve sheath diameter (ONSD) relative to patient position and ventilator settings, these changes do not appear to manifest in in-vivo models.[40][41] Several small studies have shown no significant change in ONSD with changes to patient position, the elevation of positive end-expiratory pressure, or even the artificial creation of pneumoperitoneum in laparoscopic surgeries.[42][43][44]
Technique or Treatment
After applying a sterile dressing over a closed eye and copious ultrasound gel, the high-frequency ultrasound transducer should be placed over the eye with little to no contact with the sterile dressing in the transverse plane. The sonographer's hand should be placed on a non-compressible surface (the patient's nose, midface, or forehead) to avoid direct globe pressure, discomfort, and distortion of anatomy. Small movements nasally and temporally followed by caudad and cephalad should be executed to capture the optic nerve sheath in the same plane as the AC, PC, and lens to avoid obliquing the image. Once the anechoic streak posterior to the optic disc is visualized, the image should be captured, and measurements can be taken from the saved image. The optic nerve is relatively cylindrical and symmetric, theoretically making a single view acceptable for measurement.[14]
However, the dogma of "one view is no view" should be applied in all ultrasonographic studies, and another image should be captured in the sagittal plane. After measuring 3 mm posterior to the globe, use electronic calipers to measure the distance of decreased echogenicity between the hyperechoic demarcations of the sheath. A large discrepancy between images captured in separate planes should alert the sonographer to possible artefactual or off-axis errors, and they should rescan in both planes. Once optimal images are captured in two planes, the mean should be determined to estimate the true ONSD. Both eyes should be scanned, and bilateral measurements should be considered.
If difficulty in acquiring an image during the ultrasound study is encountered, one should try to center the focal ultrasound beam transversely through the plane of the lens. The contralateral eye can be assessed to estimate the location and orientation of the pupil on the studied eye. Increasing the volume of an ultrasound gel buffer can improve the quality of the image. Increasing the gain can help enhance discernment between the actual nerve sheath and nerve. Color Doppler can help visualize the retinal artery near the posterior globe as a reference point.
Once the optic nerve sheath diameter is determined, it requires evaluation in the overall clinical context. Earlier studies have most commonly used a cutoff of 5.0 mm with excellent sensitivity as well as positive and negative predictive values, but cutoffs correlating to elevations of ICP greater than 20 mm Hg have varied from less than 5 mm to greater than 6 mm in different papers. One meta-analysis of 12 studies that compared optic nerve sheath values to CT evidence of elevated ICP yielded a specificity of 92.3% and a sensitivity of 95.6% utilizing a 5 mm cutoff in adult patients.[45]
A-mode Vs. B-mode Scan
A-mode scan is ideally advocated owing to the 'blooming' artifact during the B-mode scan.[46][47] However, it is easy to choose a distance on the optic nerve behind the globe in the B-mode scan. The B-mode scan is also easy when assessing non-compliant patients.[47] There is no significant difference in ONSD measurements with straight or lateral gaze tests on B-mode studies.[47]
Point of Measurement of ONSD
Three millimeters posterior to the globe corresponds to the bulbous (wide) portion of the optic nerve and is the site of maximum pressure changes within the nerve.[48][49][50][51] One study showed an area under the curve (AUC) of 0.956 for ONSD at 3 mm. Some studies, however, have shown no significant differences during the measurement of ONSD between 3 and 5 mm.[52]
The basic steps in measuring ONSD using ocular ultrasound can be summarized as follows:
- Supine positioning of the patient.
- The high-frequency linear probe (which allows better contrast between the nerve and the retro bulbar fat) is placed on the closed upper eyelid after applying a gel.[53]
- Acoustic output needs to be adjusted ALARA ('as low as reasonably achievable) principle to protect the lens and retina.
- The probe needs to be adjusted to display the entry of the optic nerve into the globe.
- ONSD measurement needs to be ideally taken 3 mm behind the eye globe. The point where the optic nerve and the ophthalmic artery cross is also recommended.
- Same equipment, methodology, window, contrast, and brightness are advocated.[51]
Complications
ONSUS is safe and benign in the absence of an open globe. However, if an open globe injury is suspected, there is potential for further ocular injury, and the study should not proceed without consultation or assistance from an ophthalmologist.[33][34] It is worth noting that despite the reasonably good sensitivity and specificity shown in several studies, imagining the optic nerve sheath in the traditional visual axis, and even the mean measurements of the ONSD captured in the transverse and sagittal plane, have been questioned by several authors.
Copetti et al. challenge that conventional views of the optic nerve sheath in several studies are more likely to be an artifact (potentially acoustic shadow cast from the lamina cribrosa) rather than the optic nerve itself. False positives, created by artifacts or excessive pressure on the globe itself, could result in unmerited treatment, invasive monitoring, or additional unindicated studies. Copetti suggests utilizing color doppler to identify the retinal artery and measuring the optic nerve from the lateral position.[54]
Clinical Significance
There are broad applications of ONSUS in both advanced medical centers and battlefield environments. It is often difficult and potentially life-threatening to transport critically ill intensive care unit patients to radiology suites. The mortality rate of inter-hospital transfer of critically ill patients has been reported as high as 2%, with adverse event rates as high as 68%.[55] Several studies have shown that CT scans usually result in therapeutic changes in only about half of all cases (39% to 68%); only judicious use of ICU radiographic studies should be considered.[56][57]
Head CT accounts for more than 25% of ICU inter-hospital transports, and depending on the indication, ONSUS may be a modality in improving the decision-making process for obtaining such imaging.[58] If a multisystem trauma patient with a known, stable intracranial hemorrhage and known baseline ONSD experiences a neurological decline in the ICU, it could potentially be worthwhile to perform serial ONSUS on the patient to rule out intracranial hypertension or herniation if the risks of transport are significant and evolution of the hemorrhage without intracranial hypertension would not change management. This is why it is paramount to perform early, and frequent ONSUS in patients at risk for developing increased ICP, as a significant change in ONSD is far more suggestive of changes in ICP than a single absolute number.
Medics and physicians have used ultrasound in many environments, including high altitude, polar, battlefield, and in-flight expeditions, when other imaging is not readily available.[7] Traumatic brain injury (TBI) remains a common battlefield injury, with over 200000 DoD-reported cases between 2010 to 2018. Over 80% of these TBIs are classified as mild and do not require neurosurgical intervention, but evaluation in austere locations can be difficult.[59]
ONSUS provides the ability for rapid triage and the minimally invasive evaluation of intracranial hypertension in an equivocal clinical setting and provides useful data for the early medical treatment of intracranial hypertension while arranging evacuation to definitive neurosurgical care. Though ONSUS is not specifically mentioned by the most recent Joint Trauma System Clinical Practice Guideline on Traumatic Brain/Severe Head Injury (2 March 2017), the authors note that “treatment of known or suspected intracranial hypertension remains a cornerstone of therapy in patients with severe brain injury.” Further recommendations are that after conservative management (head of the bed elevation 30 to 45 degrees, SBP goals greater than 100 to 110 mm Hg, normoventilation with PaCo2 35 to 40 mm Hg, blood glucose less than 180 mg/dl, PaO2 greater than 60 mmHg, seizure prophylaxis, etc.) treatment with 3% saline with a target serum sodium goal of 150 to 160 should be instituted if there is no contraindication. When utilizing invasive ICP monitoring, a treatment goal of less than 22 mmHg is often cited.[60][61]
Since invasive ICP monitors require some neurosurgical expertise, and traditional cutoffs of ONSD of 5 mm typically correlate to an ICP greater than 20 mmHg, ONSUS could be utilized as an aid in the decision-making process to start hypertonic therapy and as a real-time monitor of clinical effects.
A positive 30 degrees test (ONSD assessment in primary and 30 degrees from primary gaze) differentiates raised ICP due to fluid overload from that of infiltrative pathologies. [62] ‘Crescent sign’ is seen in chronic ICP compared to acute forms.[63]
Invasive methods, though considered the gold standard for ICP measurement, harbinger significant risks of infection and hemorrhage, are not readily available, and have significant financial constraints, especially in low- and middle-income nations.[64] It is a bedside, non-invasive, portable, easily performed, rapid, cheap, reproducible, efficacious, free of radiation hazards, and does not have a steep learning curve.[64][65]
Competence can be easily attained despite any formal radiology training.[65] Pocket-sized ultrasound is also now available.[66]
Limitations of the study include:
- Is operator dependent[53]
- Influence by type of settings (ER vs. ICU)[53]
- The optic nerve sheath is not perfectly circular and is a complex system comprising arachnoid trabeculae, pillars, and septa compartmentalizing the subarachnoid space[67]
- ONSD expansion persisted even after the normalization of raised ICP owing to the impaired retraction capability of the ONS[68]
- Alongside ICP, other factors may govern the optic nerve sheath in vivo
- Movement of the eyeball, axial length, myopia, lesions, and optic canal at the sphenoid bone can influence the ONSD[51]
Enhancing Healthcare Team Outcomes
ONSUS remains a relatively new modality for the assessment of ICP. Initial studies have shown that it is an extremely easy skill to acquire and can be performed bilaterally in less than 5 minutes by experienced operators.[14][45] Interestingly, research regarding the training of ONSUS in non-physician Special Operations Combat Medic (SOCM) trainees with minimal to no ultrasound experience has shown that after a 5-minute tutorial, trainees were able to obtain statistically non-significant measurement differences in ONSD when compared to expert physicians.[15]
Additional research has suggested that novice ultrasound users can obtain proficiency with this scan in as little as 25 exams, while an experienced sonographer might become proficient with as few as ten scans.[14] Given the safety profile of surface ultrasound and its expansion of utility in physician and non-physician training, the skill of ONSUS can be acquired and utilized by the entire health care team.[15] [Level 1]
Systematic review and meta-analysis have shown that ONSD of more than 5.00 to 5.70 mm has a concurrent ICP value above 20 mm Hg.[28][69] Systematic review and meta-analysis showed a mean ONSD in the included studies of 5.82 mm.[53]
ONSD/eyeball transverse diameter (mean value of 0.18) is more reliable than ONSD measurement alone.[11][47] This is accountable due to the following reasons:
- Significant correlation between ONSD and ETD
- Standard deviation between the normal and pathological values for ONSD is often overlapping
- The ratio is independent of demographic variables such as sex, height, weight, and BMI.[11]
ONSD reacts to ICP in real-time. Within the effective range, the chances of plastic deformation and over-distention of the ONS are minimal.[50][70] It is a very useful adjunct. to other standard diagnostic modalities.[53] However, unified methods and a range of ONSD values must be established. [64]
Consensus on the ONSD monitoring as a noninvasive surrogate marker of intracranial pressure monitoring has advocated a checklist for quality assurance pertaining to probe selection, patient safety, positioning, image acquisition, and methods of measurement.[71]
Nursing, Allied Health, and Interprofessional Team Interventions
In the right clinical setting or environment, ONSUS could provide enough information to institute neuroprotective measures or medical management in anticipation of further imaging, evacuation, or neurosurgical intervention. All healthcare team members should understand the ramifications of an elevated or increasing ONSD and familiarize themselves with ICP lowering techniques.
Nursing, Allied Health, and Interprofessional Team Monitoring
ONSUS can be taught to virtually any medical professional, even with limited ultrasound experience.[15] This may include paramedical, nursing, physician assistant, and physician providers. In many medical centers that offer neurosurgical services, there is not a neurosurgeon “in-house“ 24/7. Therefore, initial evaluation and interim monitoring will often be the responsibility of emergency medicine, intensive care, and nursing providers. There is a considerable utility in teaching this modality to any team that will commonly care for neurosurgical or critically ill patients.
References
- 1.
- Varsou O. The Use of Ultrasound in Educational Settings: What Should We Consider When Implementing this Technique for Visualisation of Anatomical Structures? Adv Exp Med Biol. 2019;1156:1-11. [PubMed: 31338774]
- 2.
- American College of Emergency Physicians. American College of Emergency Physicians. ACEP emergency ultrasound guidelines-2001. Ann Emerg Med. 2001 Oct;38(4):470-81. [PubMed: 11574810]
- 3.
- Beal EW, Sigmond BR, Sage-Silski L, Lahey S, Nguyen V, Bahner DP. Point-of-Care Ultrasound in General Surgery Residency Training: A Proposal for Milestones in Graduate Medical Education Ultrasound. J Ultrasound Med. 2017 Dec;36(12):2577-2584. [PubMed: 28649711]
- 4.
- Mahmood F, Matyal R, Skubas N, Montealegre-Gallegos M, Swaminathan M, Denault A, Sniecinski R, Mitchell JD, Taylor M, Haskins S, Shahul S, Oren-Grinberg A, Wouters P, Shook D, Reeves ST. Perioperative Ultrasound Training in Anesthesiology: A Call to Action. Anesth Analg. 2016 Jun;122(6):1794-804. [PubMed: 27195630]
- 5.
- Whitson MR, Mayo PH. Ultrasonography in the emergency department. Crit Care. 2016 Aug 15;20(1):227. [PMC free article: PMC4983783] [PubMed: 27523885]
- 6.
- Nations JA, Browning RF. Battlefield applications for handheld ultrasound. Ultrasound Q. 2011 Sep;27(3):171-6. [PubMed: 21873854]
- 7.
- Gharahbaghian L, Anderson KL, Lobo V, Huang RW, Poffenberger CM, Nguyen PD. Point-of-Care Ultrasound in Austere Environments: A Complete Review of Its Utilization, Pitfalls, and Technique for Common Applications in Austere Settings. Emerg Med Clin North Am. 2017 May;35(2):409-441. [PubMed: 28411935]
- 8.
- Roque PJ, Hatch N, Barr L, Wu TS. Bedside ocular ultrasound. Crit Care Clin. 2014 Apr;30(2):227-41, v. [PubMed: 24606775]
- 9.
- Helmke K, Hansen HC. Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension II. Patient study. Pediatr Radiol. 1996 Oct;26(10):706-10. [PubMed: 8805600]
- 10.
- Moretti R, Pizzi B. Ultrasonography of the optic nerve in neurocritically ill patients. Acta Anaesthesiol Scand. 2011 Jul;55(6):644-52. [PubMed: 21463263]
- 11.
- Zhu S, Cheng C, Zhao D, Zhao Y, Liu X, Zhang J. The clinical and prognostic values of optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in comatose patients with supratentorial lesions. BMC Neurol. 2021 Jul 02;21(1):259. [PMC free article: PMC8252315] [PubMed: 34215217]
- 12.
- Liu D, Kahn M. Measurement and relationship of subarachnoid pressure of the optic nerve to intracranial pressures in fresh cadavers. Am J Ophthalmol. 1993 Nov 15;116(5):548-56. [PubMed: 8238213]
- 13.
- Hylkema C. Optic Nerve Sheath Diameter Ultrasound and the Diagnosis of Increased Intracranial Pressure. Crit Care Nurs Clin North Am. 2016 Mar;28(1):95-9. [PubMed: 26873762]
- 14.
- Tayal VS, Neulander M, Norton HJ, Foster T, Saunders T, Blaivas M. Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients. Ann Emerg Med. 2007 Apr;49(4):508-14. [PubMed: 16997419]
- 15.
- Betcher J, Becker TK, Stoyanoff P, Cranford J, Theyyunni N. Military trainees can accurately measure optic nerve sheath diameter after a brief training session. Mil Med Res. 2018 Dec 20;5(1):42. [PMC free article: PMC6300875] [PubMed: 30572931]
- 16.
- Caffery TS, Perret JN, Musso MW, Jones GN. Optic nerve sheath diameter and lumbar puncture opening pressure in nontrauma patients suspected of elevated intracranial pressure. Am J Emerg Med. 2014 Dec;32(12):1513-5. [PubMed: 25284485]
- 17.
- Hassen GW, Al-Juboori M, Koppel B, Akfirat G, Kalantari H. Real time optic nerve sheath diameter measurement during lumbar puncture. Am J Emerg Med. 2018 Apr;36(4):736.e1-736.e3. [PubMed: 29338967]
- 18.
- Singleton J, Dagan A, Edlow JA, Hoffmann B. Real-time optic nerve sheath diameter reduction measured with bedside ultrasound after therapeutic lumbar puncture in a patient with idiopathic intracranial hypertension. Am J Emerg Med. 2015 Jun;33(6):860.e5-7. [PubMed: 25595270]
- 19.
- Karmaniolou I, Petropoulos G, Theodoraki K. Management of idiopathic intracranial hypertension in parturients: anesthetic considerations. Can J Anaesth. 2011 Jul;58(7):650. [PubMed: 21519980]
- 20.
- Atanassoff PG, Alon E, Weiss BM, Lauper U. Spinal anaesthesia for caesarean section in a patient with brain neoplasma. Can J Anaesth. 1994 Feb;41(2):163-4. [PubMed: 8131237]
- 21.
- Sitanaya SN, Kamayanti F, Nugroho HA, Prabowo B. Comparing ultrasonographic optic nerve sheath diameter to head computed tomography scan to predict intracranial pressure elevation. SAGE Open Med. 2022;10:20503121221077834. [PMC free article: PMC8859652] [PubMed: 35198210]
- 22.
- Cannata G, Pezzato S, Esposito S, Moscatelli A. Optic Nerve Sheath Diameter Ultrasound: A Non-Invasive Approach to Evaluate Increased Intracranial Pressure in Critically Ill Pediatric Patients. Diagnostics (Basel). 2022 Mar 21;12(3) [PMC free article: PMC8946972] [PubMed: 35328319]
- 23.
- Hanafi MG, Verki MM, Parei SN. Ultrasonic Assessment of Optic Nerve Sheath to Detect Increased Intracranial Pressure. J Med Ultrasound. 2019 Apr-Jun;27(2):69-74. [PMC free article: PMC6607883] [PubMed: 31316215]
- 24.
- Dağdelen K, Ekici M. Measuring optic nerve sheath diameter using ultrasonography in patients with idiopathic intracranial hypertension. Arq Neuropsiquiatr. 2022 Jun;80(6):580-585. [PMC free article: PMC9387182] [PubMed: 35613208]
- 25.
- Korsbæk JJ, Hagen SM, Schytz HW, Vukovic-Cvetkovic V, Wibroe EA, Hamann S, Jensen RH. Transorbital sonography: A non-invasive bedside screening tool for detection of pseudotumor cerebri syndrome. Cephalalgia. 2022 Oct;42(11-12):1116-1126. [PubMed: 35469442]
- 26.
- Wang LJ, Zhang Y, Li C, Liu Y, Dong YN, Cui L, Xing YQ. Ultrasonographic optic nerve sheath diameter as a noninvasive marker for intracranial hypotension. Ther Adv Neurol Disord. 2022;15:17562864211069744. [PMC free article: PMC8851947] [PubMed: 35186123]
- 27.
- Kalim Z, Siddiqui OA, Nadeem A, Hasan M, Rashid H. Assessment of Optic Nerve Sheath Diameter and Its Postoperative Regression among Patients Undergoing Brain Tumor Resection in a Tertiary Care Center. J Neurosci Rural Pract. 2022 Apr;13(2):270-275. [PMC free article: PMC9187386] [PubMed: 35694055]
- 28.
- Gauthey M, Tessaro MO, Breitbart S, Kulkarni AV, Davis AL. Reliability and feasibility of optic nerve point-of-care ultrasound in pediatric patients with ventricular shunts. Childs Nerv Syst. 2022 Jul;38(7):1289-1295. [PubMed: 35441844]
- 29.
- Şık N, Ulusoy E, Çitlenbik H, Öztürk A, Er A, Yılmaz D, Duman M. The role of sonographic optic nerve sheath diameter measurements in pediatric head trauma. J Ultrasound. 2022 Dec;25(4):957-963. [PMC free article: PMC9705618] [PubMed: 35396696]
- 30.
- Patel R, Chowdhury MAB, Gul S, Fahy BG, Gonzalez A, Fitzpatrick D, DePortu G, Weeks E, Elie-Turenne MC, Ocampo S, Ponnaluri S, Pizzi MA. Ultrasound of Optic Nerve Sheath Diameter and Stroke Outcomes. Crit Care Explor. 2021 Nov;3(11):e0565. [PMC free article: PMC8613366] [PubMed: 34841250]
- 31.
- Oliveira BDD, Lima FO, Homem HDC, Figueirêdo AA, Freire VMB, Maia Carvalho FM. Optic Nerve Sheath Diameter Detects Intracranial Hypertension in Acute Malignant Middle Cerebral Artery Infarction. J Stroke Cerebrovasc Dis. 2022 Mar;31(3):106276. [PubMed: 35032755]
- 32.
- Xu H, Li Y, Liu J, Chen Z, Chen Q, Xiang Y, Zhang M, He W, Zhuang Y, Yang Y, Chen W, Chen Y. Dilated Optic Nerve Sheath Diameter Predicts Poor Outcome in Acute Spontaneous Intracerebral Hemorrhage. Cerebrovasc Dis. 2022;51(2):199-206. [PubMed: 34569518]
- 33.
- Bates A, Goett HJ. StatPearls [Internet]. StatPearls Publishing; Treasure Island (FL): Jul 24, 2023. Ocular Ultrasound. [PubMed: 29083793]
- 34.
- Kilker BA, Holst JM, Hoffmann B. Bedside ocular ultrasound in the emergency department. Eur J Emerg Med. 2014 Aug;21(4):246-53. [PubMed: 24002686]
- 35.
- Canakci Y, Koksal O, Durak VA. The value of bedside ocular ultrasound assessment of optic nerve sheath diameter in the detection of increased intracranial pressure in patients presenting to the emergency room with headache. Niger J Clin Pract. 2018 Jun;21(6):778-782. [PubMed: 29888727]
- 36.
- Matalia J, Shirke S, Kekatpure M. An alternate technique for assessing optic nerve in papilledema by ultrasound B scan. Am J Emerg Med. 2015 Jul;33(7):971-3. [PubMed: 25921967]
- 37.
- Cherry PM. Rupture of the globe. Arch Ophthalmol. 1972 Nov;88(5):498-507. [PubMed: 4634787]
- 38.
- Chronopoulos A, Ong JM, Thumann G, Schutz JS. Occult globe rupture: diagnostic and treatment challenge. Surv Ophthalmol. 2018 Sep-Oct;63(5):694-699. [PubMed: 29649485]
- 39.
- Engelbert PR, Palma JK. Petroleum Jelly: A Novel Medium for Ocular Ultrasound. J Emerg Med. 2015 Aug;49(2):172-4. [PubMed: 26014760]
- 40.
- Romagnuolo L, Tayal V, Tomaszewski C, Saunders T, Norton HJ. Optic nerve sheath diameter does not change with patient position. Am J Emerg Med. 2005 Sep;23(5):686-8. [PubMed: 16140179]
- 41.
- Kim SH, Kim HJ, Jung KT. Position does not affect the optic nerve sheath diameter during laparoscopy. Korean J Anesthesiol. 2015 Aug;68(4):358-63. [PMC free article: PMC4524934] [PubMed: 26257848]
- 42.
- Verdonck P, Kalmar AF, Suy K, Geeraerts T, Vercauteren M, Mottrie A, De Wolf AM, Hendrickx JF. Optic nerve sheath diameter remains constant during robot assisted laparoscopic radical prostatectomy. PLoS One. 2014;9(11):e111916. [PMC free article: PMC4219812] [PubMed: 25369152]
- 43.
- You AH, Song Y, Kim DH, Suh J, Baek JW, Han DW. Effects of positive end-expiratory pressure on intraocular pressure and optic nerve sheath diameter in robot-assisted laparoscopic radical prostatectomy: A randomized, clinical trial. Medicine (Baltimore). 2019 Apr;98(14):e15051. [PMC free article: PMC6455825] [PubMed: 30946349]
- 44.
- Chin JH, Kim WJ, Lee J, Han YA, Lim J, Hwang JH, Cho SS, Kim YK. Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial. PLoS One. 2017;12(1):e0170369. [PMC free article: PMC5249217] [PubMed: 28107408]
- 45.
- Ohle R, McIsaac SM, Woo MY, Perry JJ. Sonography of the Optic Nerve Sheath Diameter for Detection of Raised Intracranial Pressure Compared to Computed Tomography: A Systematic Review and Meta-analysis. J Ultrasound Med. 2015 Jul;34(7):1285-94. [PubMed: 26112632]
- 46.
- De Bernardo M, Vitiello L, De Pascale I, Capasso L, Cornetta P, Rosa N. Optic Nerve Ultrasound Evaluation in Idiopathic Intracranial Hypertension. Front Med (Lausanne). 2022;9:845554. [PMC free article: PMC8921495] [PubMed: 35299843]
- 47.
- Kim DH, Jun JS, Kim R. Ultrasonographic measurement of the optic nerve sheath diameter and its association with eyeball transverse diameter in 585 healthy volunteers. Sci Rep. 2017 Nov 21;7(1):15906. [PMC free article: PMC5698472] [PubMed: 29162911]
- 48.
- Robba C, Santori G, Czosnyka M, Corradi F, Bragazzi N, Padayachy L, Taccone FS, Citerio G. Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2018 Aug;44(8):1284-1294. [PubMed: 30019201]
- 49.
- Kim DH, Jun JS, Kim R. Measurement of the Optic Nerve Sheath Diameter with Magnetic Resonance Imaging and Its Association with Eyeball Diameter in Healthy Adults. J Clin Neurol. 2018 Jul;14(3):345-350. [PMC free article: PMC6032005] [PubMed: 29856162]
- 50.
- Wang LJ, Chen LM, Chen Y, Bao LY, Zheng NN, Wang YZ, Xing YQ. Ultrasonography Assessments of Optic Nerve Sheath Diameter as a Noninvasive and Dynamic Method of Detecting Changes in Intracranial Pressure. JAMA Ophthalmol. 2018 Mar 01;136(3):250-256. [PMC free article: PMC5885896] [PubMed: 29392301]
- 51.
- Vaiman M, Gottlieb P, Bekerman I. Quantitative relations between the eyeball, the optic nerve, and the optic canal important for intracranial pressure monitoring. Head Face Med. 2014 Aug 17;10:32. [PMC free article: PMC4141911] [PubMed: 25130267]
- 52.
- Petrou S, Raio C, Klein L, Felicetta M. Posterior Globe Depth for Optic Nerve Sheath Diameter Measurement in Ocular Ultrasound in Healthy Volunteers. J Ultrasound Med. 2022 Oct;41(10):2425-2430. [PubMed: 34927283]
- 53.
- Montorfano L, Yu Q, Bordes SJ, Sivanushanthan S, Rosenthal RJ, Montorfano M. Mean value of B-mode optic nerve sheath diameter as an indicator of increased intracranial pressure: a systematic review and meta-analysis. Ultrasound J. 2021 Jul 02;13(1):35. [PMC free article: PMC8253877] [PubMed: 34215966]
- 54.
- Copetti R, Cattarossi L. Optic nerve ultrasound: artifacts and real images. Intensive Care Med. 2009 Aug;35(8):1488-9; author reply 1490-1. [PubMed: 19367390]
- 55.
- Beckmann U, Gillies DM, Berenholtz SM, Wu AW, Pronovost P. Incidents relating to the intra-hospital transfer of critically ill patients. An analysis of the reports submitted to the Australian Incident Monitoring Study in Intensive Care. Intensive Care Med. 2004 Aug;30(8):1579-85. [PubMed: 14991102]
- 56.
- Aliaga M, Forel JM, De Bourmont S, Jung B, Thomas G, Mahul M, Bisbal M, Nougaret S, Hraiech S, Roch A, Chaumoitre K, Jaber S, Gainnier M, Papazian L. Diagnostic yield and safety of CT scans in ICU. Intensive Care Med. 2015 Mar;41(3):436-43. [PubMed: 25518950]
- 57.
- Caruana M, Culp K. Intrahospital transport of the critically ill adult: a research review and implications. Dimens Crit Care Nurs. 1998 May-Jun;17(3):146-56. [PubMed: 9633345]
- 58.
- Indeck M, Peterson S, Smith J, Brotman S. Risk, cost, and benefit of transporting ICU patients for special studies. J Trauma. 1988 Jul;28(7):1020-5. [PubMed: 3135417]
- 59.
- Lazarus R, Helmick K, Malik S, Gregory E, Agimi Y, Marion D. Continuum of the United States military's traumatic brain injury care: adjusting to the changing battlefield. Neurosurg Focus. 2018 Dec 01;45(6):E15. [PubMed: 30544329]
- 60.
- Brain Trauma Foundation. American Association of Neurological Surgeons. Congress of Neurological Surgeons. Joint Section on Neurotrauma and Critical Care, AANS/CNS. Bratton SL, Chestnut RM, Ghajar J, McConnell Hammond FF, Harris OA, Hartl R, Manley GT, Nemecek A, Newell DW, Rosenthal G, Schouten J, Shutter L, Timmons SD, Ullman JS, Videtta W, Wilberger JE, Wright DW. Guidelines for the management of severe traumatic brain injury. IX. Cerebral perfusion thresholds. J Neurotrauma. 2007;24 Suppl 1:S59-64. [PubMed: 17511547]
- 61.
- Carney N, Totten AM, O'Reilly C, Ullman JS, Hawryluk GW, Bell MJ, Bratton SL, Chesnut R, Harris OA, Kissoon N, Rubiano AM, Shutter L, Tasker RC, Vavilala MS, Wilberger J, Wright DW, Ghajar J. Guidelines for the Management of Severe Traumatic Brain Injury, Fourth Edition. Neurosurgery. 2017 Jan 01;80(1):6-15. [PubMed: 27654000]
- 62.
- Caffery TS, Musso MW. Questions regarding the utility of the 30-degree test in measuring optic nerve sheath diameters in ED patients. Am J Emerg Med. 2015 Apr;33(4):595-6. [PubMed: 25744151]
- 63.
- Bhosale A, Shah VM, Shah PK. Accuracy of crescent sign on ocular ultrasound in diagnosing papilledema. World J Methodol. 2017 Sep 26;7(3):108-111. [PMC free article: PMC5618144] [PubMed: 29026691]
- 64.
- Bittencourt Rynkowski C, Caldas J. Ten Good Reasons to Practice Neuroultrasound in Critical Care Setting. Front Neurol. 2021;12:799421. [PMC free article: PMC8793827] [PubMed: 35095741]
- 65.
- Dinsmore M, Venkatraghavan L. Clinical applications of point-of-care ultrasound in brain injury: a narrative review. Anaesthesia. 2022 Jan;77 Suppl 1:69-77. [PubMed: 35001377]
- 66.
- Johnson GGRJ, Jelic T, Derksen A, Unger B, Zeiler FA, Ziesmann MT, Gillman LM. Accuracy of Optic Nerve Sheath Diameter Measurements in Pocket-Sized Ultrasound Devices in a Simulation Model. Front Med (Lausanne). 2022;9:831778. [PMC free article: PMC8924410] [PubMed: 35308521]
- 67.
- Killer HE, Laeng HR, Flammer J, Groscurth P. Architecture of arachnoid trabeculae, pillars, and septa in the subarachnoid space of the human optic nerve: anatomy and clinical considerations. Br J Ophthalmol. 2003 Jun;87(6):777-81. [PMC free article: PMC1771732] [PubMed: 12770980]
- 68.
- Wu GB, Tian J, Liu XB, Wang ZY, Guo JY. Can optic nerve sheath diameter assessment be used as a non-invasive tool to dynamically monitor intracranial pressure? J Integr Neurosci. 2022 Mar 22;21(2):54. [PubMed: 35364642]
- 69.
- Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2011 Jul;37(7):1059-68. [PubMed: 21505900]
- 70.
- Chen LM, Wang LJ, Hu Y, Jiang XH, Wang YZ, Xing YQ. Ultrasonic measurement of optic nerve sheath diameter: a non-invasive surrogate approach for dynamic, real-time evaluation of intracranial pressure. Br J Ophthalmol. 2019 Apr;103(4):437-441. [PMC free article: PMC6691934] [PubMed: 30361274]
- 71.
- Hirzallah MI, Lochner P, Hafeez MU, Lee AG, Krogias C, Dongarwar D, Manchanda R, Ouellette L, Hartman ND, Ertl M, Schlachetzki F, Robba C. Quality assessment of optic nerve sheath diameter ultrasonography: Scoping literature review and Delphi protocol. J Neuroimaging. 2022 Sep;32(5):808-824. [PubMed: 35711135]
Disclosure: Evan Richards declares no relevant financial relationships with ineligible companies.
Disclosure: Sunil Munakomi declares no relevant financial relationships with ineligible companies.
Disclosure: Dana Mathew declares no relevant financial relationships with ineligible companies.
- Continuing Education Activity
- Introduction
- Anatomy and Physiology
- Indications
- Contraindications
- Equipment
- Personnel
- Preparation
- Technique or Treatment
- Complications
- Clinical Significance
- Enhancing Healthcare Team Outcomes
- Nursing, Allied Health, and Interprofessional Team Interventions
- Nursing, Allied Health, and Interprofessional Team Monitoring
- Review Questions
- References
- Review Detection of increased intracranial pressure by ultrasound.[J Spec Oper Med. 2012]Review Detection of increased intracranial pressure by ultrasound.Hightower S, Chin EJ, Heiner JD. J Spec Oper Med. 2012 Fall; 12(3):19-22.
- Evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement.[Ultrasound J. 2023]Evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement.Moore BT, Osika T, Satterly S, Shah S, Thirion T, Hampton S, Aylward S, Montgomery S. Ultrasound J. 2023 Aug 2; 15(1):33. Epub 2023 Aug 2.
- Trauma intensive care unit (TICU) at Hamad General Hospital.[Qatar Med J. 2019]Trauma intensive care unit (TICU) at Hamad General Hospital.Chughtai T, Parchani A, Strandvik G, Verma V, Arumugam S, El-Menyar A, Rizoli S, Al-Thani H. Qatar Med J. 2019; 2019(2):5. Epub 2020 Feb 6.
- Review Optic Nerve Sheath Diameter Ultrasound and the Diagnosis of Increased Intracranial Pressure.[Crit Care Nurs Clin North Am. ...]Review Optic Nerve Sheath Diameter Ultrasound and the Diagnosis of Increased Intracranial Pressure.Hylkema C. Crit Care Nurs Clin North Am. 2016 Mar; 28(1):95-9. Epub 2015 Dec 23.
- Review Optic Nerve Ultrasound Evaluation in Children: A Review.[Diagnostics (Basel). 2023]Review Optic Nerve Ultrasound Evaluation in Children: A Review.Abbinante G, Vitiello L, Coppola A, Salerno G, Gagliardi V, Pellegrino A. Diagnostics (Basel). 2023 Feb 1; 13(3). Epub 2023 Feb 1.
- Optic Nerve Sheath Ultrasound - StatPearlsOptic Nerve Sheath Ultrasound - StatPearls
Your browsing activity is empty.
Activity recording is turned off.
See more...