U.S. flag

An official website of the United States government

NCBI Bookshelf. A service of the National Library of Medicine, National Institutes of Health.

StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024 Jan-.

Cover of StatPearls

StatPearls [Internet].

Show details

Alkaline Phosphatase

; ; ; .

Author Information and Affiliations

Last Update: October 29, 2023.

Introduction

Alkaline phosphatases (ALPs) are a group of isoenzymes located on the outer layer of the cell membrane. They catalyze the hydrolysis of organic phosphate esters found in the extracellular space. Zinc and magnesium are essential cofactors of this enzyme. Despite the diverse tissue distribution and varying physiochemical properties of ALPs, they are classified as true isoenzymes due to their shared ability to catalyze the same reaction.

ALP is found in the cytosol of liver cells and the canalicular membrane of hepatocytes.[1] ALP is found in decreasing concentrations in various organs such as the placenta, ileal mucosa, kidney, bone, and liver. Over 80% of the ALP in serum originates from the liver and bone, with minor contributions from the intestine. Although ALPs are present in various tissues throughout the body, their precise physiological function remains elusive.[2]

ALPs are categorized into 2 types—tissue-specific and tissue-nonspecific. Tissue-specific ALPs are exclusively present in the intestine, placenta, and germinal tissue,[3] specifically within the tissues where they are expressed under physiological conditions. Under specific conditions, the tissue-specific ALPs may also contribute to the circulating pool of serum ALP when there is increased stimulation of their production.

The tissue-nonspecific ALPs are clinically significant, as they constitute most of the circulating fraction in serum.[4] They are encoded by a single gene and expressed in the liver, bone, and kidneys. In contrast, intestinal ALP is coded by a distinct gene separate from the one responsible for placental ALP and the Regan isoenzyme. Excessive amounts of intestinal ALP are produced in Hodgkin lymphoma.[5] Although all tissue-nonspecific ALPs share the identical amino acid sequence, they possess distinct carbohydrate and lipid side chains. These unique physicochemical properties are conferred through post-translational modifications.[6]

Etiology and Epidemiology

Serum ALP levels exhibit age-related variations in healthy individuals. The levels are highest during childhood and puberty due to bone growth and development and then decrease as individuals age. The decline in serum ALP levels within the age group of 15 to 50 is slightly more pronounced in men than in women.[1] These levels increase again during old age, with a notable gender distribution difference. The underlying reasons for these typical fluctuations remain unidentified. Research indicates a positive correlation between body weight and smoking, while an inverse correlation exists with height.[7]

In healthy individuals, the predominant source of the circulating enzyme is the liver and bone. In some individuals, a minor fraction of this enzyme originates from the intestinal tract.[8] Consuming a fatty meal leads to increased serum ALP levels in individuals with blood groups O and B, primarily due to contributions from the intestinal tract. As this elevation can persist for up to 12 hours in the serum, it is advisable to assess serum enzyme levels in a fasting state.[9]

Pathophysiology

Human ALPs (hALP) are tethered to the cell membrane via glycosylphosphatidylinositol. Their release into the serum occurs through the action of specific phospholipase enzymes.[10] These enzymes have a half-life of 7 days, and their clearance from the serum is independent of the bile duct's patency or the liver's functional capacity. However, the precise site where ALP degradation occurs remains unknown. Serum ALP levels may remain elevated for up to one week after the resolution of biliary obstruction.[1]

The liver is the primary source in most patients with elevated enzyme levels. The subsequent most probable contributor is increased osteoblast activity, which is observed in bone disorders or usually during periods of growth. In addition, in the late third trimester, the influx of placental ALP contributes significantly to elevated levels in pregnant women.[11]

The mechanism behind the elevation of ALP in hepatobiliary disorders has been debated. However, research has provided convincing evidence that this increase results from heightened enzyme synthesis rather than a reduction in hepatobiliary excretion of the enzyme.[11] The increase in hepatic enzyme activity directly corresponds to the elevation in serum ALP activity. This is primarily attributed to an upsurge in the translation of the mRNA of ALP—a process facilitated by the increasing bile acid concentration—and increased secretion of ALP into the serum through canalicular leakage into the hepatic sinusoid. The precise mechanism that precipitates its release into circulation has not been elucidated.[1]

Studies indicate that vesicles containing ALP, along with various enzymes attached to the sinusoidal membranes, are detected in the serum of patients with cholestasis. As ALP is newly synthesized as a response to biliary obstruction, its serum level may appear normal in the initial stages of acute biliary obstruction, even when serum aminotransferases have already reached their peak.[12]

Specimen Requirements and Procedure

Blood should be collected after a minimum 8-hour fasting period—both serum and heparinized plasma yield comparable results. Although minor hemolysis is acceptable, it is essential to prevent gross hemolysis. Specific sample storage conditions can lead to an elevation in serum ALP. Notably, enzyme activity substantially increases when refrigerated or frozen sera are warmed.[13]

In fresh serum, ALP activity can increase by as much as 2% within 6 hours at 25 °C. Substantial increases in ALP activity up to 30% are observed upon thawing frozen serum or reconstituting lyophilized specimens. These increases may be due to the release of ALP from complexes with lipoproteins or potentially due to heightened activity of the non-complexed enzyme. For optimal results, it is advisable to analyze ALP specimens on the same day they are collected.[14] Using standard phlebotomy procedures, the specimen can be collected in either a plain red-top tube or a speckled-red-top tube with gel as a serum separator. To prevent contamination, it is essential not to draw tubes containing anticoagulants before using the red-top or speckled-red-top tubes.[15]

Diagnostic Tests

Various clinical methods are available to assess serum ALP levels, distinguished by the substrate used, alkaline pH buffer, and established normal reference values. These tests, in principle, rely on the enzyme's ability to hydrolyze phosphate esters.[16] In the most widely used international method, p-nitrophenol phosphate serves as the substrate, while amino alcohol is used as the buffering agent. The rate at which p-nitrophenol phosphate is released from the substrate serves as a measurable marker of ALP activity, and the outcomes are typically expressed in international units per liter (IU/L).[17] Various methods appear equally effective in identifying abnormal values associated with different clinical conditions. Comparing results obtained from different tests can be straightforward by using multiples of the upper limit of the established normal range.[18]

Electrophoresis, as a standalone method, does not consistently distinguish between the isoenzymes, as the electrophoretic mobility of bone and liver isoenzymes exhibits only slight differences. Therefore, a more dependable approach involves electrophoresis on cellulose acetate in conjunction with heat inactivation. Although not widely accessible, the most accurate method for precisely identifying liver, bone, intestinal, and placental isoenzymes utilizes polyacrylamide gel slab-based separation.[19] 

Testing Procedures

The ALP test is performed on semiautomatic or fully automated analyzers that operate on the principle of photometry. Photometry entails the quantification of light absorption within the ultraviolet (UV), visible (VIS), and infrared (IR) spectrum range. This measurement determines the amount of a particular analyte in a solution or liquid. Photometers utilize a specific light source and detectors capable of converting the light transmitted through a sample solution into an electrical signal proportionate to the light's intensity. These detectors can include photodiodes, photoresistors, or photomultipliers.[20]

Photometry applies Beer-Lambert law to compute coefficients derived from transmittance measurements. A test-specific calibration function establishes a correlation between absorbance and analyte concentration, resulting in highly accurate measurements.[21] The electrophoresis technique is most commonly used for distinguishing between ALP isozymes and isoforms. However, due to potential overlap between the fractions, combining electrophoresis with another separation technique can yield more dependable results.[22] Notably, a direct immunochemical method is currently accessible for measuring bone-related ALP.[23]

The liver fraction exhibits the swiftest migration in electrophoresis, followed by bone, placental, and intestinal fractions. Due to the similarity between liver and bone phosphatases, a distinct demarcation between them is often challenging to achieve. Accurate quantitation using a densitometer can be difficult due to the overlap between the 2 peaks. The liver isoenzyme can be further subdivided into 2 fractions—the major liver band and a smaller fraction, which is referred to as fast liver or α1 liver. The fast liver fraction migrates to the major band anodally, corresponding to the α1 fraction observed in protein electrophoresis.[19]

The major liver fraction is most commonly raised in cases of elevated total ALP levels. Many hepatobiliary conditions lead to elevations of this fraction, typically occurring early in the progression of the disease. The fast-liver fraction has been observed in metastatic liver carcinoma and other hepatobiliary diseases.[24] The fast-liver fraction often indicates obstructive liver disease, but it can also be found without a discernible disease state.[25]

A second approach used to determine the source of an elevated ALP is based on the difference in heat stability.[26] Generally, ALP activity is assessed both before and after subjecting the serum to heating at 56 °C for 10 minutes. If the residual activity after heating is less than 20% of the total activity before heating, it indicates that the ALP elevation is attributed to bone phosphatase. When more than 20% of the activity persists after heating, the elevation is likely due to liver phosphatase. These conclusions are drawn from the observation that the 4 major fractions exhibit varying heat stabilities, with placental ALP being the most heat-resistant, followed by intestinal, liver, and bone fractions in decreasing order of heat stability. Placental ALP, for instance, can withstand heat denaturation at 65 °C for 30 minutes.[11] 

Heat inactivation is an imprecise method for differentiation because inactivation depends on several factors, including precise temperature control, timing, and the requirement for analytical methods sensitive enough to detect even minor residual ALP activity. Moreover, there is a degree of overlap between the heat inactivation profiles of liver and bone fractions, both in liver and bone diseases, further complicating differentiation.[27]

The third approach for distinguishing ALP isoenzymes is based on selective chemical inhibition, with phenylalanine as one of the inhibitors utilized. Phenylalanine demonstrates a significantly greater inhibitory effect on intestinal and placental ALP than liver and bone ALP. Nonetheless, using phenylalanine does not enable the differentiation of placental from intestinal ALP or liver from bone ALP.[28]

In addition to the 4 major ALP isoenzyme fractions, certain abnormal fractions are associated with neoplasms. The most commonly encountered among these are the Regan and Nagao isoenzymes,[29] often referred to as carcinoplacental ALPs due to their similarities to the placental isoenzyme. The Regan isoenzyme has the highest heat stability among all ALP isoenzymes and can withstand denaturation at 65 °C for 30 minutes. The Regan isoenzyme migrates to the same position as the bone fraction, and its activity is inhibited by phenylalanine.[30] The Nagao isoenzyme can be considered a variation of the Regan isoenzyme, with identical electrophoresis, heat stability, and phenylalanine inhibition characteristics.[31] However, Nagao isoenzyme can be inhibited by L-leucine, and it has been identified in metastatic carcinoma of pleural surfaces and adenocarcinoma of the pancreas and bile duct.[32]

Interfering Factors

ALP is inhibited by metal-complexing anticoagulants, as they impede the enzyme by forming complexes with Mg and Zn, and therefore, they should be avoided. Hemolyzed or lipemic specimens should be rejected if they exhibit a high background absorbance. Significantly, bilirubin at concentrations of up to 20 mg/dL does not interfere with ALP measurements.[33] 

The purity of the transphosphorylation buffer is highly critical. In addition, it has been discovered that diethanolamine (DEA) sources can contain notable levels of monoethanolamine (MEA)—a potent inhibitor of ALP. Over time, DEA solutions can degrade during storage, resulting in the concurrent generation of MEA.[34] Certain commercial p-nitrophenol phosphate substrate preparations may contain excessive quantities of p-nitrophenol or inorganic phosphate, or even both. The presence of p-nitrophenol leads to elevated blank absorbance, while inorganic phosphate acts as an inhibitor to ALP.[35]

Serum ALP levels are affected by many factors, including medications, physical conditions, herbal remedies, dietary choices, smoking, alcohol consumption, and pregnancy. Over 1,000 drugs, herbs, and physiological conditions affecting ALP activity have been documented. For example, clofibrate can lower serum ALP activity, reducing all ALP fractions except the liver. This effect may result from an enhanced biliary clearance of ALP.[36] Estrogens, individually or in conjunction with androgens, have been observed to have a suppressive effect on ALP activity. However, separate studies have noted that both estrogens and androgens can elevate serum ALP activity. The reduction in ALP activity observed with estrogen therapy may be attributed to a decreased rate of bone turnover.[37]

Verapamil, commonly prescribed for managing cardiac arrhythmias, angina pectoris, and essential hypertension, has been found to elevate serum ALP levels in hypertensive patients. After administering verapamil to hypertensive patients for a 2-month duration, there is a significant rise in total ALP activity, followed by an increase in bone ALP levels in the serum. These findings indicate that verapamil may affect bone metabolism, secondary to increased parathyroid hormone secretion.[38] Furthermore, any medication that is hepatotoxic or induces cholestasis can lead to a notable elevation in serum ALP, at times to a significant extent.[39]

ALP assays are susceptible to negative interference due to alkali denaturation of hemoglobin, resulting in a negative offset in absorbance readings. Icterus primarily influences chemistry tests through spectrophotometric and chemical interferences. Bilirubin absorbs light within the 400 to 540 nm range, with its peak absorption around 460 nm.[40] Colorimetric assays that rely on primary or secondary absorbance measurements within these wavelength ranges may encounter interference. Notably, unconjugated and conjugated forms of bilirubin may exert different effects on certain assays. In many cases, conjugated bilirubin has been observed to induce a more pronounced interference.[41]

Results, Reporting, and Critical Findings

When ALP is the sole liver biochemical test that shows elevation, while serum aminotransferases remain within the normal range, or when ALP exhibits a disproportionately high increase compared to other liver biochemical tests, it is imperative to concentrate on identifying the cause and origin of this isolated or disproportionate elevation in ALP. For asymptomatic patients with isolated serum ALP elevation, it is crucial to pinpoint the primary source of the abnormality.[10] ALPs derived from the liver, bone, placenta, and intestines have different physicochemical properties.[42]

One approach involves measuring the activity of enzymes, such as 5’-nucleotidase (5NT) and gamma-glutamyl transpeptidase (GGT), which increase in concordance with the liver ALP. These enzymes do not exhibit elevations in bone disorders and demonstrate a strong correlation with hepatobiliary disorders. Serum GGT is highly sensitive to biliary tract diseases but exhibits lower specificity for liver disorders.[43] The 5NT levels may become elevated in pregnant patients. However, in non-pregnant patients, it is relatively specific for liver disorders and demonstrates a strong correlation with serum ALP of hepatic origin. Notably, the absence of an elevated 5NT in the presence of elevated ALP does not necessarily exclude hepatobiliary disease, as they may not rise simultaneously in early or mild hepatic injury cases.[44]

Clinical Significance

The principal clinical significance of measuring serum ALP levels is diagnosing cholestatic liver disease, as some of the most substantial ALP elevations are observed in patients with cholestasis. Usually, elevations 4-fold or more above the upper limit of normal can be found in up to 75% of patients with cholestasis, whether intrahepatic or extrahepatic.[10] The degree of elevation does not help in distinguishing the 2 types of cholestasis. Similar elevations are observed in cases of biliary obstruction due to cancer (cholangiocarcinoma, pancreatic head adenocarcinoma, or ampullary adenocarcinoma), choledocholithiasis, biliary stricture, sclerosing cholangitis, or causes of intrahepatic cholestasis such as primary biliary cholangitis (PBC), drug-induced liver injury, chronic rejection of liver allografts, infiltrative liver diseases (sarcoidosis, amyloidosis, tuberculosis, and liver metastasis), and severe alcoholic hepatitis leading to steatonecrosis.[45] Patients with AIDS may also exhibit notably high levels of ALP, often stemming from cholangiopathy related to opportunistic infections such as cytomegalovirus, cryptosporidiosis, or granulomatous liver involvement from tuberculosis.[46]

Moderate elevation of serum ALP, which can reach up to 4 times the upper limit of normal, is nonspecific, as it can manifest in various liver-related conditions, including cirrhosis, chronic hepatitis, viral hepatitis, congestive heart failure, and ischemic cholangiopathy.[47] Notably, disorders that do not primarily involve the liver, such as intra-abdominal infections, cholestasis of sepsis, Hodgkin lymphoma, myeloid metaplasia, and osteomyelitis, can also lead to a moderate elevation of serum ALP.[10]

Both primary and metastatic cancers elevate serum ALP levels through local bile duct obstruction and an augmented leakage of the liver isoenzyme.[48] Primary extrahepatic cancer does not necessarily have to affect the liver or bone directly. Certain tumors can generate their own ALP in rare instances, such as Hodgkin lymphoma secreting the Regan isoenzyme. Alternatively, they can induce a paraneoplastic effect that causes leakage of the hepatic isoenzyme into the circulation, as seen in Stauffer syndrome due to renal cell carcinoma.[49]

Abnormally low ALP levels can offer clinical insights, particularly in cases of Wilson disease, particularly when it presents in a fulminant form with hemolysis. This is attributed to the displacement of zinc, a cofactor of ALP, by copper in Wilson's disease, a condition characterized by copper overload, resulting in diminished ALP levels.[50] Other factors leading to low ALP levels include zinc deficiency, pernicious anemia, hypothyroidism, and congenital hypophosphatasia.[51]

Transient very high levels of ALP, reaching up to 30 times the upper reference limit, have been documented in children. However, the clinical significance of this finding is unknown. This phenomenon has been termed "transient hyperphosphatasemia" and may involve either the bone or liver isoenzyme.[52] Typically, affected patients are asymptomatic and exhibit an unremarkable medical history, physical examination, and laboratory results. Some patients may have recently experienced mild viral conditions.[53]

Extensive evaluation is usually unnecessary for patients with only a mild elevation of serum ALP, which is less than a 50% increase. These individuals can be clinically monitored with periodic assessments of serum liver biochemical tests. However, when ALP levels are significantly elevated, it is imperative to conduct further evaluation to determine whether the source is hepatic or non-hepatic.[54] The simultaneous elevation of either GGT or 5NT indicates a hepatic source for an elevated ALP level. If the source is non-hepatic, the next step involves assessing potential underlying undiagnosed disorders. Elevated bone ALP levels can be observed in cases of bone metastasis, Paget disease, osteogenic sarcoma, healing fractures, hyperparathyroidism, hyperthyroidism, and osteomalacia. Elevated intestinal fraction of ALP often occurs after a fatty meal and can be hereditary; however, it typically does not necessitate further evaluation.[55] When the liver is suspected as the source, it is crucial to conduct imaging of the biliary tree to distinguish between extrahepatic or intrahepatic cholestasis while also reviewing the patient's medication list.[45]

In most cases, the initial imaging study ordered is right upper quadrant ultrasonography. If the bile duct is dilated, the choice between endoscopic retrograde cholangiopancreatography (ERCP) or magnetic resonance cholangiopancreatography (MRCP) depends on the clinical indication. On the other hand, if the bile duct does not exhibit dilation, the recommended next step is to test for serum antimitochondrial antibody (AMA) to assess for PBC.[56] If the serum AMA level is within the normal range, it becomes essential to evaluate for causes of intrahepatic cholestasis, AMA-negative PBC, sarcoidosis, and other conditions mentioned earlier. In many cases, a liver biopsy is the ultimate diagnostic test used in such situations, as it aids in pinpointing the underlying cause of the elevated serum ALP.[57]

Quality Control and Lab Safety

A quality management system (QMS) is crucial for laboratory tests as it assures the reliability of all aspects of laboratory operations.[58] In the context of laboratories, quality is characterized by the accuracy, reliability, and timeliness of reported test results. A poor QMS can lead to unwarranted treatment or complications, the inability to provide accurate treatment, delayed diagnoses, and unnecessary follow-up diagnostic testing. Implementing a QMS in a laboratory setting effectively ensures that quality control (QC) and quality assurance goals are met and maintained.[59]

QC, often called internal QC, entails monitoring a measurement procedure to verify that results for patient samples meet performance specifications appropriate for patient care. QC also helps identify any error conditions that require correction.[60] When the result for a QC material falls within the acceptable limits of the expected value, it confirms the stability of the measurement procedure, indicating that it is functioning as anticipated. Therefore, results for patient samples can be reported with a high probability that they are suitable for clinical use. If a QC result is not within acceptable limits, it signals a malfunction in the measurement procedure. In such cases, there is a high probability that results for patient samples may not be appropriate for clinical use, thereby necessitating corrective action.[61] If corrective action is indicated, patient sample measurements should be reprocessed once the measurement procedure has been restored to its stable and accurate performance condition. If erroneous results are reported before the error condition is identified, a corrected report must be issued.[62]

QC materials are measured periodically along with patient samples. For non-waived tests, laboratory regulations mandate analyzing at least 2 levels of control materials once every 24 hours. Laboratories have the flexibility to analyze QC samples more frequently if it is deemed necessary to ensure accurate results. QC samples should be assayed after an analyzer's calibration or maintenance to verify the correct method performance. To streamline QC when conducting tests for which the manufacturers' recommendations are less frequent than those mandated by the regulatory agency, for instance, once per month,[63] laboratories can establish an individualized QC plan (IQCP). This involves conducting a risk assessment to identify potential sources of errors in all testing phases and implementing a QC strategy to minimize the likelihood of errors. Patient results can also be incorporated into a statistical QC process to monitor the performance of the measurement procedure.[64]

The Levey-Jennings plot is the most commonly used format for evaluating QC results. This format displays each QC result sequentially over time, enabling a rapid visual performance assessment. Provided that the measurement procedure is carried out under stable conditions in accordance with its specifications, the mean value serves as the target (or expected) value for the QC result, while the standard deviation (SD) lines depict the anticipated imprecision. Assuming a Gaussian (normal) distribution of imprecision, the results should exhibit a uniform distribution around the mean, with outcomes being more frequently observed closer to the mean than at the extremes of the distribution.[65] The conventional method of expressing QC interpretive rules involves using an abbreviation nomenclature popularized in clinical laboratories by Westgard.[66]

External QC, also called external quality assessment (EQA) or proficiency testing (PT), is a monitoring process in which surrogate samples are received from an independent external organization, and the laboratory is not aware of the expected values for these samples. The results for the EQA/PT samples are transmitted to the provider and then compared with results from other laboratories to assess whether a laboratory's measurement procedures align with the expected performance. Notably, the quality of the EQA/PT sample plays a crucial role in interpreting the results.[67] The acceptable performance (accuracy) for ALP assays, defined by the Clinical Laboratory Improvement Amendments of 1988 (CLIA-88), is within the range of the target value ± 30%. The College of American Pathologists (CAP) also utilizes this same acceptability criteria in its surveys.[68] To meet the requirements, a laboratory must attain a score of 80% or higher in each testing event for each analyte and maintain an overall score of 80% or greater across all analytes. Each laboratory is responsible for establishing its acceptability criteria for intra-daily and inter-daily variations, which should be determined based on the specific instrument and quality-control materials in use.[69]

Every clinical laboratory must establish and maintain a comprehensive and formal safety program as its utmost priority. This program is the cornerstone of ensuring the well-being of both patients and laboratory personnel. It offers a structured framework for identifying, mitigating, and managing potential hazards associated with laboratory operations. By adhering to stringent safety protocols, the laboratory significantly reduces the risk of errors, accidents, and exposure to hazardous materials.[70] Barrier protection, including gloves, masks, protective eyewear, and gowns, must be readily available and consistently utilized during blood collection procedures and when handling all patient specimens. Gloves should be disposable, made of nonsterile latex, or constructed from other materials that offer sufficient barrier protection. Phlebotomists must change gloves and dispose of them properly when transitioning between drawing blood from different patients, and they should also wash their hands whenever gloves are changed.[71] 

Facial barrier protection should be used if there is a significant risk of blood or body fluids spatter. Lab technicians should minimize the use of syringes whenever possible and ensure the disposal of needles into rigid containers without manual handling. All sharps should be disposed of appropriately. Furthermore, they should wear protective clothing as an effective barrier against potentially infectious materials. Upon leaving the laboratory, lab technicians should remove their protective clothing. Frequent hand washing is crucial in the laboratory. Employees should wash their hands whenever they exit the laboratory. Notably, warning labels should not be used on patient specimens; all specimens should be treated as potentially hazardous.[72] Biosafety level 2 procedures should be used whenever appropriate. Discarded tubes or infected materials should never be left unattended or unlabeled. Periodic cleaning of the freezer and dry-ice chests is necessary to remove broken ampoules and tubes of biological specimens. Using rubber gloves and respiratory protection during this cleaning process is mandatory.[73]

The Occupational Safety and Health Administration (OSHA) mandates that the hepatitis B vaccine must be offered to all employees at risk of potential exposure as a regular or occasional part of their dutCDC'sThe CDC's Advisory Committee on Immunization Practices recommends that medical technologists, phlebotomists, and pathologists receive the hepatitis B vaccine. Therefore, it is a regulatory requirement that all laboratory employees mentioned above are, at a minimum, provided with the option to receive a free hepatitis B vaccine.[74] 

In 2003, the International Organization for Standardization introduced the ISO 15190 standard to enable medical laboratories of various types to establish policies and procedures that foster a secure working environment within their facilities.[75] This standard is tailored explicitly for safety considerations and covers a broad spectrum of laboratory safety aspects, including managerial requirements and individual personnel's responsibilities, such as fire and radiation safety measures. These safety directives are based on the principles of QMS, which involve clearly defined roles and responsibilities, for instance, the Laboratory Director and Safety Officer, task delegation for employees, and a system of regular audits, continuous assessment, and improvement.[76] 

Enhancing Healthcare Team Outcomes

A healthcare provider may order an ALP test for a routine checkup or if the patient displays symptoms of a bone disorder or liver damage. A thorough evaluation and classification of any aberrant ALP levels and related observations by the patient's healthcare team are pivotal for enhancing healthcare outcomes for the patient. 

Review Questions

References

1.
Green MR, Sambrook J. Alkaline Phosphatase. Cold Spring Harb Protoc. 2020 Aug 03;2020(8):100768. [PubMed: 32747588]
2.
Vimalraj S. Alkaline phosphatase: Structure, expression and its function in bone mineralization. Gene. 2020 Sep 05;754:144855. [PubMed: 32522695]
3.
Azpiazu D, Gonzalo S, Villa-Bellosta R. Tissue Non-Specific Alkaline Phosphatase and Vascular Calcification: A Potential Therapeutic Target. Curr Cardiol Rev. 2019;15(2):91-95. [PMC free article: PMC6520574] [PubMed: 30381085]
4.
Zaher DM, El-Gamal MI, Omar HA, Aljareh SN, Al-Shamma SA, Ali AJ, Zaib S, Iqbal J. Recent advances with alkaline phosphatase isoenzymes and their inhibitors. Arch Pharm (Weinheim). 2020 May;353(5):e2000011. [PubMed: 32128876]
5.
Lallès JP. Intestinal alkaline phosphatase: novel functions and protective effects. Nutr Rev. 2014 Feb;72(2):82-94. [PubMed: 24506153]
6.
Dixon IMC. Tissue non-specific alkaline phosphatase (TNAP): A player in post-MI cardiac fibrosis. EBioMedicine. 2021 Jun;68:103430. [PMC free article: PMC8213913] [PubMed: 34134085]
7.
Brichacek AL, Brown CM. Alkaline phosphatase: a potential biomarker for stroke and implications for treatment. Metab Brain Dis. 2019 Feb;34(1):3-19. [PMC free article: PMC6351214] [PubMed: 30284677]
8.
Crofton PM. Biochemistry of alkaline phosphatase isoenzymes. Crit Rev Clin Lab Sci. 1982;16(3):161-94. [PubMed: 7047076]
9.
Matsushita M, Harajiri S, Tabata S, Yukimasa N, Muramoto Y, Komoda T. [Alkaline phosphatase activity in blood group B or O secretors is fluctuated by the dinner intake of previous night]. Rinsho Byori. 2013 Apr;61(4):307-12. [PubMed: 23855186]
10.
Sharma U, Pal D, Prasad R. Alkaline phosphatase: an overview. Indian J Clin Biochem. 2014 Jul;29(3):269-78. [PMC free article: PMC4062654] [PubMed: 24966474]
11.
Masrour Roudsari J, Mahjoub S. Quantification and comparison of bone-specific alkaline phosphatase with two methods in normal and paget's specimens. Caspian J Intern Med. 2012 Summer;3(3):478-83. [PMC free article: PMC3755844] [PubMed: 24009918]
12.
Pike AF, Kramer NI, Blaauboer BJ, Seinen W, Brands R. A novel hypothesis for an alkaline phosphatase 'rescue' mechanism in the hepatic acute phase immune response. Biochim Biophys Acta. 2013 Dec;1832(12):2044-56. [PubMed: 23899605]
13.
Wieczorek E. [Nocturnal intragastric administration of phosphates in the treatment of familial hypophosphatemic rickets]. Pediatr Pol. 1986 Sep;61(9):563-70. [PubMed: 3031573]
14.
Plebani M. Errors in clinical laboratories or errors in laboratory medicine? Clin Chem Lab Med. 2006;44(6):750-9. [PubMed: 16729864]
15.
McDonough PG. Pre-analytical errors: everything that happens to the specimen up to the point of testing. Fertil Steril. 2002 Apr;77(4):857-8. [PubMed: 11937155]
16.
Sancenon V, Goh WH, Sundaram A, Er KS, Johal N, Mukhina S, Carr G, Dhakshinamoorthy S. Development, validation and quantitative assessment of an enzymatic assay suitable for small molecule screening and profiling: A case-study. Biomol Detect Quantif. 2015 Jun;4:1-9. [PMC free article: PMC4822204] [PubMed: 27077032]
17.
Tietz NW, Burtis CA, Duncan P, Ervin K, Petitclerc CJ, Rinker AD, Shuey D, Zygowicz ER. A reference method for measurement of alkaline phosphatase activity in human serum. Clin Chem. 1983 May;29(5):751-61. [PubMed: 6404566]
18.
Hoekstra LT, de Graaf W, Nibourg GA, Heger M, Bennink RJ, Stieger B, van Gulik TM. Physiological and biochemical basis of clinical liver function tests: a review. Ann Surg. 2013 Jan;257(1):27-36. [PubMed: 22836216]
19.
Siede WH, Seiffert UB. Quantitative alkaline phosphatase isoenzyme determination by electrophoresis on cellulose acetate membranes. Clin Chem. 1977 Jan;23(1):28-34. [PubMed: 832369]
20.
Ni P, Xie J, Chen C, Jiang Y, Zhao Z, Zhang Y, Lu Y, Yu J. Spectrophotometric determination of the activity of alkaline phosphatase and detection of its inhibitors by exploiting the pyrophosphate-accelerated oxidase-like activity of nanoceria. Mikrochim Acta. 2019 May 02;186(5):320. [PubMed: 31049712]
21.
Wang J, Ni P, Chen C, Jiang Y, Zhang C, Wang B, Cao B, Lu Y. Colorimetric determination of the activity of alkaline phosphatase by exploiting the oxidase-like activity of palladium cube@CeO2 core-shell nanoparticles. Mikrochim Acta. 2020 Jan 09;187(2):115. [PubMed: 31919598]
22.
Warnes TW, Hine P, Kay G. Polyacrylamide gel disc electrophoresis of alkaline phosphatase isoenzymes in bone and liver disease. J Clin Pathol. 1976 Sep;29(9):782-7. [PMC free article: PMC476179] [PubMed: 977779]
23.
Milinković N, Sarić-Matutinović M, Pejanović S, Ignjatović S. Comparison between bone alkaline phosphatase immunoassay and electrophoresis technique in hemodialysis patients. J Med Biochem. 2020 Jan 23;39(2):178-183. [PMC free article: PMC7526026] [PubMed: 33033450]
24.
Rosalki SB, Foo AY. Two new methods for separating and quantifying bone and liver alkaline phosphatase isoenzymes in plasma. Clin Chem. 1984 Jul;30(7):1182-6. [PubMed: 6547374]
25.
Moss DW. Alkaline phosphatase isoenzymes. Clin Chem. 1982 Oct;28(10):2007-16. [PubMed: 6751596]
26.
Iino S. [Clinical significance of alkaline phosphatase isozyme analysis]. Nihon Rinsho. 1995 May;53(5):1157-61. [PubMed: 7602772]
27.
Farley JR, Hall SL, Herring S, Libanati C, Wergedal JE. Reference standards for quantification of skeletal alkaline phosphatase activity in serum by heat inactivation and lectin precipitation. Clin Chem. 1993 Sep;39(9):1878-84. [PubMed: 8375064]
28.
Puukka R. Comparison of alkaline phosphatase isoenzymes determined by an inhibition method and by electrophoresis. Clin Chim Acta. 1978 Apr 17;85(2):111-4. [PubMed: 647973]
29.
Fishman WH. Immunology and biochemistry of the Regan isoenzyme. Prostate. 1980;1(4):399-410. [PubMed: 7024957]
30.
Moss DW. Diagnostic aspects of alkaline phosphatase and its isoenzymes. Clin Biochem. 1987 Aug;20(4):225-30. [PubMed: 3319285]
31.
Nozawa S, Arai H, Widjaja T, Tsukazaki K, Ohta H, Kurihara S. [Biochemical studies on alkaline phosphatase isoenzyme profile in endometrial cancer]. Nihon Sanka Fujinka Gakkai Zasshi. 1984 Mar;36(3):369-76. [PubMed: 6201574]
32.
Jardillier JC. [The isoenzymes of the alkaline phosphatases and their cancerologic biochemistries prospects (author's transl)]. Ann Biol Clin (Paris). 1981;39(3):115-20. [PubMed: 7247086]
33.
Bowen RA, Remaley AT. Interferences from blood collection tube components on clinical chemistry assays. Biochem Med (Zagreb). 2014;24(1):31-44. [PMC free article: PMC3936985] [PubMed: 24627713]
34.
Knaak JB, Leung HW, Stott WT, Busch J, Bilsky J. Toxicology of mono-, di-, and triethanolamine. Rev Environ Contam Toxicol. 1997;149:1-86. [PubMed: 8956558]
35.
Niina N, Kodamatani H, Uozumi K, Kokufu Y, Saito K, Yamazaki S. Simultaneous detection of monoethanolamine, diethanolamine, and triethanolamine by HPLC with a chemiluminescence reaction and online derivatization to tertiary amine. Anal Sci. 2005 May;21(5):497-500. [PubMed: 15913135]
36.
Horning K, Schmidt C. Azathioprine-Induced Rapid Hepatotoxicity. J Pharm Technol. 2014 Feb;30(1):18-20. [PMC free article: PMC5990130] [PubMed: 34860888]
37.
Fraser MO, Arslan M, Plant TM. Androgen and estrogen treatment, alone or in combination, differentially influences bone maturation and hypothalamic mechanisms that time puberty in the male rhesus monkey (Macaca mulatta). Pediatr Res. 2005 Jan;57(1):141-8. [PubMed: 15557106]
38.
Sjödén G, Rosenqvist M, Kriegholm E, Nordenström J, Björkhem I. Verapamil increases serum alkaline phosphatase in hypertensive patients. J Intern Med. 1990 Oct;228(4):339-42. [PubMed: 2266342]
39.
David S, Hamilton JP. Drug-induced Liver Injury. US Gastroenterol Hepatol Rev. 2010 Jan 01;6:73-80. [PMC free article: PMC3160634] [PubMed: 21874146]
40.
Wang Z, Guo H, Wang Y, Kong F, Wang R. Interfering effect of bilirubin on the determination of alkaline phosphatase. Int J Clin Exp Med. 2014;7(11):4244-8. [PMC free article: PMC4276196] [PubMed: 25550938]
41.
Pyles LA, Stejskal EJ, Einzig S. Spectrophotometric measurement of plasma 2-thiobarbituric acid-reactive substances in the presence of hemoglobin and bilirubin interference. Proc Soc Exp Biol Med. 1993 Apr;202(4):407-19. [PubMed: 8456104]
42.
Stigbrand T. Present status and future trends of human alkaline phosphatases. Prog Clin Biol Res. 1984;166:3-14. [PubMed: 6504935]
43.
Martin JM, Goldberg DM. Activities of gamma-glutamyl transferase, 5'-nucleotidase and alkaline phosphatase in human duodenal aspirate. Enzyme. 1986;35(4):189-96. [PubMed: 2877869]
44.
Takeuchi A, Shibuya A. [5'-Nucleotidase]. Nihon Rinsho. 1999 Aug;57 Suppl:483-5. [PubMed: 10503478]
45.
Shamban L, Patel B, Williams M. Significantly Elevated Liver Alkaline Phosphatase in Congestive Heart Failure. Gastroenterology Res. 2014 Apr;7(2):64-68. [PMC free article: PMC5051077] [PubMed: 27785272]
46.
Gao Y, Chin K, Mishriki YY. AIDS Cholangiopathy in an Asymptomatic, Previously Undiagnosed Late-Stage HIV-Positive Patient from Kenya. Int J Hepatol. 2011;2011:465895. [PMC free article: PMC3170813] [PubMed: 21994858]
47.
Šmíd V. Liver tests. Cas Lek Cesk. 2022 Spring;161(2):52-56. [PubMed: 35728957]
48.
Demers LM, Costa L, Lipton A. Biochemical markers and skeletal metastases. Cancer. 2000 Jun 15;88(12 Suppl):2919-26. [PubMed: 10898335]
49.
Fontes-Sousa M, Magalhães H, da Silva FC, Maurício MJ. Stauffer's syndrome: A comprehensive review and proposed updated diagnostic criteria. Urol Oncol. 2018 Jul;36(7):321-326. [PubMed: 29657090]
50.
Sakurai Y, Higashiguchi T. Transient hyperphosphatasemia: Possible association with pediatric acute respiratory infection. Pediatr Investig. 2021 Jun;5(2):94-98. [PMC free article: PMC8212759] [PubMed: 34179704]
51.
Whyte MP. Hypophosphatasia: An overview For 2017. Bone. 2017 Sep;102:15-25. [PubMed: 28238808]
52.
Arthur LJ, Hill PG, Attenburrow AA. Transient hyperphosphatasaemia. Arch Dis Child. 1984 Oct;59(10):996-7. [PMC free article: PMC1628844] [PubMed: 6497440]
53.
Schonhaut B L, Rocha R A. [Benign transient hyperphosphatasaemia in infants: Clinical series]. Rev Chil Pediatr. 2017 Feb;88(1):169-175. [PubMed: 28288234]
54.
Verma J, Gorard DA. Persistently elevated alkaline phosphatase. BMJ Case Rep. 2012 Aug 24;2012 [PMC free article: PMC4544100] [PubMed: 22922932]
55.
Assy N, Jacob G, Spira G, Edoute Y. Diagnostic approach to patients with cholestatic jaundice. World J Gastroenterol. 1999 Jun;5(3):252-262. [PMC free article: PMC4688481] [PubMed: 11819442]
56.
Revzin MV, Scoutt LM, Garner JG, Moore CL. Right Upper Quadrant Pain: Ultrasound First! J Ultrasound Med. 2017 Oct;36(10):1975-1985. [PubMed: 28586152]
57.
Siddique A, Kowdley KV. Approach to a patient with elevated serum alkaline phosphatase. Clin Liver Dis. 2012 May;16(2):199-229. [PMC free article: PMC3341633] [PubMed: 22541695]
58.
Wadhwa V, Rai S, Thukral T, Chopra M. Laboratory quality management system: road to accreditation and beyond. Indian J Med Microbiol. 2012 Apr-Jun;30(2):131-40. [PubMed: 22664426]
59.
Allen LC. Role of a quality management system in improving patient safety - laboratory aspects. Clin Biochem. 2013 Sep;46(13-14):1187-93. [PubMed: 23648455]
60.
Ricós C, Fernandez-Calle P, Perich C, Westgard JO. Internal quality control - past, present and future trends. Adv Lab Med. 2022 Oct;3(3):243-262. [PMC free article: PMC10197334] [PubMed: 37362142]
61.
Loh TP, Lim CY, Sethi SK, Tan RZ, Markus C. Advances in internal quality control. Crit Rev Clin Lab Sci. 2023 Nov;60(7):502-517. [PubMed: 37194676]
62.
Kinns H, Pitkin S, Housley D, Freedman DB. Internal quality control: best practice. J Clin Pathol. 2013 Dec;66(12):1027-32. [PubMed: 24072731]
63.
Yago M, Pla C. Reference-mean-centered statistical quality control. Clin Chem Lab Med. 2020 Aug 27;58(9):1517-1523. [PubMed: 31926071]
64.
Bruno LC. IQCP: Guideline and Helpful Tools for Implementation. Lab Med. 2016 Nov;47(4):e42-e46. [PubMed: 27708173]
65.
Khatri R, K C S, Shrestha P, Sinha JN. Implementing self sustained quality control procedures in a clinical laboratory. JNMA J Nepal Med Assoc. 2013 Jan-Mar;52(189):233-7. [PubMed: 23591302]
66.
Poh DKH, Lim CY, Tan RZ, Markus C, Loh TP. Internal quality control: Moving average algorithms outperform Westgard rules. Clin Biochem. 2021 Dec;98:63-69. [PubMed: 34534518]
67.
James D, Ames D, Lopez B, Still R, Simpson W, Twomey P. External quality assessment: best practice. J Clin Pathol. 2014 Aug;67(8):651-5. [PubMed: 24621574]
68.
Born PH, Thran SL. The influence of CLIA '88 on physician office laboratories. J Fam Pract. 1998 Apr;46(4):319-27. [PubMed: 9564374]
69.
Badrick T. Integrating quality control and external quality assurance. Clin Biochem. 2021 Sep;95:15-27. [PubMed: 33965412]
70.
Keckler MS, Anderson K, McAllister S, Rasheed JK, Noble-Wang J. Development and implementation of evidence-based laboratory safety management tools for a public health laboratory. Saf Sci. 2019 Aug;117:205-216. [PMC free article: PMC6537614] [PubMed: 31156293]
71.
Ialongo C, Bernardini S. Phlebotomy, a bridge between laboratory and patient. Biochem Med (Zagreb). 2016;26(1):17-33. [PMC free article: PMC4783087] [PubMed: 26981016]
72.
Tice AD. Bloodborne pathogen exposure and recommendations for management. J Infus Nurs. 2002 Nov-Dec;25(6 Suppl):S5-9. [PubMed: 12555021]
73.
Ta L, Gosa L, Nathanson DA. Biosafety and Biohazards: Understanding Biosafety Levels and Meeting Safety Requirements of a Biobank. Methods Mol Biol. 2019;1897:213-225. [PMC free article: PMC7120677] [PubMed: 30539447]
74.
Byrd KK, Lu PJ, Murphy TV. Hepatitis B vaccination coverage among health-care personnel in the United States. Public Health Rep. 2013 Nov-Dec;128(6):498-509. [PMC free article: PMC3804093] [PubMed: 24179261]
75.
Noble MA. ISO 15190:2003 Medical Laboratories - Requirements for Safety. EJIFCC. 2004 Dec;15(4):141-143. [PMC free article: PMC6028787] [PubMed: 29977184]
76.
Orelle A, Nikiema A, Zakaryan A, Albetkova AA, Keita MS, Rayfield MA, Peruski LF, Pierson A. A Multilingual Tool for Standardized Laboratory Biosafety and Biosecurity Assessment and Monitoring. Health Secur. 2022 Nov-Dec;20(6):488-496. [PMC free article: PMC9805837] [PubMed: 36383124]

Disclosure: Dhruv Lowe declares no relevant financial relationships with ineligible companies.

Disclosure: Terrence Sanvictores declares no relevant financial relationships with ineligible companies.

Disclosure: Muhammad Zubair declares no relevant financial relationships with ineligible companies.

Disclosure: Savio John declares no relevant financial relationships with ineligible companies.

Copyright © 2024, StatPearls Publishing LLC.

This book is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) ( http://creativecommons.org/licenses/by-nc-nd/4.0/ ), which permits others to distribute the work, provided that the article is not altered or used commercially. You are not required to obtain permission to distribute this article, provided that you credit the author and journal.

Bookshelf ID: NBK459201PMID: 29083622

Views

  • PubReader
  • Print View
  • Cite this Page

Related information

  • PMC
    PubMed Central citations
  • PubMed
    Links to PubMed

Similar articles in PubMed

See reviews...See all...

Recent Activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...