U.S. flag

An official website of the United States government

Format

Send to:

Choose Destination

Links from BioSample

ERX4191206: Illumina HiSeq 2500 sequencing; RNA-seq of a degenerated spoIIE deficient Clostridium beijerinckii NCIMB 8052 at 4, 11 and 24 hours of fermentation
1 ILLUMINA (Illumina HiSeq 2500) run: 6.8M spots, 444.9M bases, 184.7Mb downloads

Design: RNA-seq of a degenerated spoIIE deficient Clostridium beijerinckii NCIMB 8052 at 4, 11 and 24 hours of fermentation
Submitted by: Wageningen Food & Biobased Research
Study: RNA-seq of a degenerated spoIIE deficient Clostridium beijerinckii NCIMB 8052 at 4, 11 and 24 hours of fermentation
show Abstracthide Abstract
To understand the impact of strain degeneration on the transcriptome we performed fermentations and RNA seq analysis to on a degenerated C.berijeirnckii strain.
Sample: Sample 6
SAMEA6941539 • ERS4651429 • All experiments • All runs
Library:
Name: Sample 6_s
Instrument: Illumina HiSeq 2500
Strategy: RNA-Seq
Source: TRANSCRIPTOMIC
Selection: Inverse rRNA
Layout: SINGLE
Construction protocol: Total RNA was isolated from C. beijerinckii NCIMB 8052 for transcriptome studies. Samples were taken from biological triplicate of 400-mL fermentations from cells in early exponential, acetogenic, and solventogenic phase. Cells were pelleted for 15 min at 3000 × g and 4 °C, washed 3 times with sterile H2O and stored at -80 °C until further use. Fermentations were performed at 35 °C in 400 mL working volume of CM2 medium containing (in g L-1): yeast extract, 1.00; KH2PO4, 1.00; K2HPO4, 0.61; MgSO4 × 7 H2O, 1.00; FeSO4 × 7 H2O, 0.0066; para-aminobenzoic acid, 0.10; and ammonium acetate, 2.90 and with either 50.0 glucose. Frozen samples were thawed on ice and RNA was isolated using high pure RNA isolation kit (Roche Diagnostics, Basel, Switzerland). Quality and concentration of RNA samples were checked using a nanodrop machine (Thermo Fisher Scientific, Waltham, Massachusetts, USA). The absence of DNA in the RNA samples was evaluated by qPCR analysis performed with BioRad CFX 96 Touch™. The RNA quality and integrity were determined using the Qsep 100 bioanalyzer (Bioptic Inc.). Messenger-RNA was depleted with the Ribo-Zero Magnetic Kit and a 250-300 bp insert cDNA library was constructed using the Illumina True seq stranded kit.
Experiment attributes:
Experimental Factor: time: 11
Runs: 1 run, 6.8M spots, 444.9M bases, 184.7Mb
Run# of Spots# of BasesSizePublished
ERR42304406,845,017444.9M184.7Mb2020-07-01

ID:
11238738

Supplemental Content

Recent activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...