Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection

Eur J Vasc Endovasc Surg. 2015 Oct;50(4):450-9. doi: 10.1016/j.ejvs.2015.04.035. Epub 2015 Jun 19.

Abstract

Objective: This study evaluates the safety and efficacy of pre-placement of a distal bare stent as an adjunct to thoracic endovascular aortic repair (TEVAR) in the setting of complicated acute Stanford type B aortic dissection (cTBAD).

Methods: The records of all patients diagnosed with cTBAD at the institution between 2010 and 2013 were reviewed. Indications for the pre-placement of a distal bare stent included symptomatic malperfusion and/or radiological evidence of true lumen collapse. Computed tomography angiography was performed post-operatively to assess aortic remodeling.

Results: 148 patients were treated for cTBAD: 113 patients (76.4%) were treated with standard TEVAR and 35 (23.6%) were treated by combined proximal TEVAR with pre-placement of an adjunctive distal bare stent. Primary technical success was 95.9%. The 30 day mortality rate was 4.1% and was not different between groups. The 30 day morbidity included transient renal failure (10.1%), endoleak (7.4%), and paraplegia (2.7%), and was not different between groups. The mean follow up was 10 months (range 2-12 months). No late stent complications were observed; patients with an adjunctive bare stent had less distal re-dissection (0% vs. 15%; p = .01) and fewer endovascular re-interventions (5.7% vs. 20.4%; p = .04). At 1 year, patients treated with TEVAR and an adjunctive distal bare stent had increased true lumen volume (166 vs. 110 mL; p = .022), decreased false lumen volume (60 vs. 90 mL; p = .043), and increased complete false lumen thrombosis in the thoracic (76.5% vs. 29.5%; p < .001) and abdominal (20.6% vs. 3.8%; p = .002) segments.

Conclusions: Combined pre-placement of a distal bare stent as an adjunct to proximal TEVAR to treat cTBAD restricts oversizing of the distal stent graft, reducing the potential for distal true lumen collapse and visceral malperfusion, and improving remodeling of the dissected thoracic aorta. Long-term follow up and prospective studies are needed to assess the overall effectiveness of this treatment strategy.

Keywords: Aortic remodeling; Bare stent; Stent graft; Type B aortic dissection.

MeSH terms

  • Acute Disease
  • Adult
  • Aorta, Thoracic / diagnostic imaging
  • Aorta, Thoracic / physiopathology
  • Aorta, Thoracic / surgery*
  • Aortic Aneurysm, Thoracic / diagnosis
  • Aortic Aneurysm, Thoracic / mortality
  • Aortic Aneurysm, Thoracic / physiopathology
  • Aortic Aneurysm, Thoracic / surgery*
  • Aortic Dissection / diagnosis
  • Aortic Dissection / mortality
  • Aortic Dissection / physiopathology
  • Aortic Dissection / surgery*
  • Aortography / methods
  • Blood Vessel Prosthesis Implantation* / instrumentation
  • Blood Vessel Prosthesis Implantation* / methods
  • Blood Vessel Prosthesis Implantation* / mortality
  • Blood Vessel Prosthesis*
  • China
  • Endovascular Procedures* / instrumentation
  • Endovascular Procedures* / methods
  • Endovascular Procedures* / mortality
  • Female
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications / therapy
  • Prosthesis Design
  • Recurrence
  • Retrospective Studies
  • Stents*
  • Time Factors
  • Tomography, X-Ray Computed
  • Treatment Outcome
  • Vascular Remodeling*