Enhancing the detection of barcoded reads in high throughput DNA sequencing data by controlling the false discovery rate

BMC Bioinformatics. 2014 Aug 7;15(1):264. doi: 10.1186/1471-2105-15-264.

Abstract

Background: DNA barcodes are short unique sequences used to label DNA or RNA-derived samples in multiplexed deep sequencing experiments. During the demultiplexing step, barcodes must be detected and their position identified. In some cases (e.g., with PacBio SMRT), the position of the barcode and DNA context is not well defined. Many reads start inside the genomic insert so that adjacent primers might be missed. The matter is further complicated by coincidental similarities between barcode sequences and reference DNA. Therefore, a robust strategy is required in order to detect barcoded reads and avoid a large number of false positives or negatives.For mass inference problems such as this one, false discovery rate (FDR) methods are powerful and balanced solutions. Since existing FDR methods cannot be applied to this particular problem, we present an adapted FDR method that is suitable for the detection of barcoded reads as well as suggest possible improvements.

Results: In our analysis, barcode sequences showed high rates of coincidental similarities with the Mus musculus reference DNA. This problem became more acute when the length of the barcode sequence decreased and the number of barcodes in the set increased. The method presented in this paper controls the tail area-based false discovery rate to distinguish between barcoded and unbarcoded reads. This method helps to establish the highest acceptable minimal distance between reads and barcode sequences. In a proof of concept experiment we correctly detected barcodes in 83% of the reads with a precision of 89%. Sensitivity improved to 99% at 99% precision when the adjacent primer sequence was incorporated in the analysis. The analysis was further improved using a paired end strategy. Following an analysis of the data for sequence variants induced in the Atp1a1 gene of C57BL/6 murine melanocytes by ultraviolet light and conferring resistance to ouabain, we found no evidence of cross-contamination of DNA material between samples.

Conclusion: Our method offers a proper quantitative treatment of the problem of detecting barcoded reads in a noisy sequencing environment. It is based on the false discovery rate statistics that allows a proper trade-off between sensitivity and precision to be chosen.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • DNA / genetics*
  • DNA Contamination
  • DNA Primers / genetics
  • False Positive Reactions
  • Genome / genetics
  • High-Throughput Nucleotide Sequencing / methods*
  • High-Throughput Nucleotide Sequencing / standards
  • Mice
  • Reference Standards
  • Sequence Analysis, DNA / methods*
  • Sequence Analysis, DNA / standards
  • Sodium-Potassium-Exchanging ATPase / genetics

Substances

  • DNA Primers
  • DNA
  • Atp1a1 protein, mouse
  • Sodium-Potassium-Exchanging ATPase