The effect of aging on the fracture toughness of esthetic restorative materials

Am J Dent. 2010 Jun;23(3):142-6.

Abstract

Purpose: To compare the fracture toughness (KIc) of tooth-colored restorative materials based on a four-point bending; to assess the effect of distilled water and a resin surface sealant (G-Coat Plus) on the resistance of the materials to fracture.

Methods: Specimens were prepared from six materials: Quix Fil; Dyract (Dentsply), Freedom (SDI), Fuji VII (GC), Fuji IX (GC); Fuji II LC (GC). Fuji II LC and Fuji IX were tested both with and without applying G-Coat Plus (GC). The specimens were divided into the three groups which were conditioned in distilled water at 37 degrees C for 48 hours, 4 and 8 weeks. The specimens were loaded in a four-point bending test using a universal testing machine. The maximum load to specimen failure was recorded and the fracture toughness calculated.

Results: There were significant differences among most of the materials (P < 0.001). Quix Fil had the highest mean KIc value and Fuji VII the lowest. Immersion in distilled water for the resin composite and polyacid-modified resin composites caused a significant decrease in KIc as the time interval increased. For glass-ionomer cements, KIc decreased significantly after 4 weeks, and after 8 weeks immersion slightly increased. G-Coat Plus affected Fuji II LC positively while it had no effect on the Fuji IX.

MeSH terms

  • Coated Materials, Biocompatible
  • Compomers*
  • Composite Resins*
  • Dental Restoration, Permanent*
  • Dental Stress Analysis
  • Glass Ionomer Cements*
  • Materials Testing
  • Pliability
  • Resin Cements
  • Time Factors
  • Water

Substances

  • Coated Materials, Biocompatible
  • Compomers
  • Composite Resins
  • G-Coat Plus
  • Glass Ionomer Cements
  • Resin Cements
  • Water