Rapid magnetic-mediated solid-phase extraction and pre-concentration of selected endocrine disrupting chemicals in natural waters by poly(divinylbenzene-co-methacrylic acid) coated Fe3O4 core-shell magnetite microspheres for their liquid chromatography-tandem mass spectrometry determination

J Chromatogr A. 2010 Feb 19;1217(8):1219-26. doi: 10.1016/j.chroma.2009.12.035. Epub 2009 Dec 16.

Abstract

A new Fe(3)O(4)/poly(divinylbenzene-co-methacrylic acid) core-shell magnetite microspheric material have been successfully developed as magnetic-mediated solid-phase extraction micro-particle sorbent in dispersion mode (MM-SPE-MP) for the determination of selected estrogenic endocrine disrupting chemicals (EDCs), namely: estrone (E1), 17beta-estradiol (E2), estriol (E3), 17alpha-ethynylestradiol (EE2) and bisphenol-A (BPA), in natural water, via quantification by HPLC tandem mass spectrometry. The magnetite Fe(3)O(4) core of this MM-SPE-MP sorbent was fabricated by a solvothermal approach and the thin layer of amphipolar poly(divinylbenzene-co-methacrylic acid) (pDVB-MAA) coating was established via suspension polymerization. The resultant core-shell MM-SPE-MP sorbent material was characterized by electron microscopy, X-ray diffraction and Fourier-transformed infrared spectroscopy. Particle size distribution of the core-shell microspheres was within the range 300-700 nm in diameter and the thickness of the pDVB-MAA coating was ca. 10nm. This magnetite microspheric material can be easily dispersed in aqueous samples and retrieved by the application of external magnetic field via a small piece of permanent magnet. The MM-SPE-MP process for the selected estrogenic EDCs involved the dispersion of the core-shell microspheric sorbent in water samples with sonication, followed by magnetic aided retrieval of the sorbent and solvent (methanol) desorption of extracted EDCs for LC-MS/MS analysis. Partition equilibrium for all the selected EDCs onto this MM-SPE-MP sorbent was achieved within 15 min. Recoveries of the EDCs were in ranges of 56-111%. Analytes with smaller K(OW) value showed relatively lower recovery (and relatively longer equilibration time for partitioning). Method detection limits achieved were found to be 1-36 pg ml(-1) (n=3), while the repeatability was 6-34% (p<0.05, n=3). This work demonstrates the usefulness of MM-SPE-MP in the rapid and highly sensitive monitoring of trace organic contaminants in natural waters.

Publication types

  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Chromatography, Liquid / methods*
  • Endocrine Disruptors / analysis*
  • Ferrosoferric Oxide / chemistry
  • Limit of Detection
  • Magnetics*
  • Solid Phase Extraction / economics
  • Solid Phase Extraction / instrumentation
  • Solid Phase Extraction / methods*
  • Tandem Mass Spectrometry / methods*
  • Time Factors
  • Water / analysis*
  • Water Pollutants, Chemical / analysis

Substances

  • Endocrine Disruptors
  • Water Pollutants, Chemical
  • Water
  • Ferrosoferric Oxide